分析变电站电压无功分散控制的几种控制模式,探讨无功功率控制和功率因数控制的优缺点,提出电压无功控制限值的设定方法。
Several distributed control modes of voltage and reactive power in substation are analyzed in this paper. The advantages and shortcomings between reactive power control and power factor control are also discussed, and the setting method of limited values for voltage and reactive power control is presented.
出处
《中国电力》
CSCD
北大核心
2001年第9期58-60,共3页
Electric Power
关键词
变电站
电压无功
综合控制
限值
substation; voltage and reactive power; integrated control; limited value