期刊文献+

蓄电池低锑砷合金材料中铜的测定

Determination of copper in low Sb-As alloy in storage battery
下载PDF
导出
摘要 研究了用火焰原子吸收光谱法测定蓄电池低锑砷合金中的微量元素铜的最佳测量条件 ,包括燃助比、燃烧高度、灯电流、光谱通带以及基体元素对测定的影响。实验表明 :在选定实验条件下 ,铜的浓度在 0~ 4mg/L范围内符合比尔定律 ,相关系数 (r)为 0 9979。方法简便、快速 ,选择性好 ,结果满意。回收率在 96 %~ 97%之间 ,相对标准偏差为 1 13%。 The optimum conditions for determination of copper in Sb-As alloy in storage battery by atom absorbing spectrum of flame, including the effect of fuel ratio,flame length lamp current, spectrum and the principle elements on the determination were studied The experiment showed that under the set experimental condition, concentration from 0~4mg/L was in accordance with Beers Law, the interrelated coefficient being 0 9979 Applied to determination of copper in low Sb As alloy, this approach proved to be easy, quick and well selective, with a reclamation of 96%~97%,and relative standard deviation of 1 13%, which constituted satisfactory results
作者 李加新
出处 《电池》 CAS CSCD 北大核心 2001年第4期202-203,共2页 Battery Bimonthly
关键词 蓄电池 低锑砷合金 测定 storage battery low Sb As alloy copper determination
  • 相关文献

参考文献4

二级参考文献4

  • 1黄业初,分析试验室,1987年,6卷,2期,23页
  • 2陈焕光,分析测试通报,1985年,4卷,1期,39页
  • 3陈焕光,冶金分析与测试.冶金分析分册,1985年,5卷,1期,11页
  • 4陈焕光,林如城,李明芜,王萍,陈永兆.以5-Cl-PADAB为指示剂用EDTP光度滴定铜[J].分析试验室,1991,10(2):28-29. 被引量:4