摘要 将Low-E中空玻璃窗划分为单框双玻璃和单框三玻璃,利用WINDOW6.1软件建立单框双玻、单框三玻系统在不同镀膜位置和数量时的模型,并计算两种系统的传热系数、太阳得热系数、遮阳系数、可见光透射比和内表面温度等参数,分析以上参数对窗户能耗的影响,确定单框双玻窗和单框三玻窗玻璃系统的最佳镀膜位置。 It is analyzed the glass of low-emissivity quantity position,and it is analyzed the influence of heat transfer coefficient,solar heat gain coefficient,shading coefficient,visible light and transmittance,windows glass inner surface temperature,and other parameters on energy consumption of double-glazed of single frame window and triple-glazed of single frame window by using the WINDOW6.1 software of Lawrence Berkeley national laboratory.It is established the best coating location of double-glazed of single frame window and triple-glazed of single frame window,which provides a theoretical basis for window manufacture.
作者 李志杰
出处 《工业建筑》 CSCD 北大核心 2008年第z1期44-47,43,共5页 Industrial Construction
关键词 低辐射镀膜玻璃 单框双玻 单框三玻 传热系数 太阳得热系数 glass of low-emissivity coating double-glazed of single frame triple-glazed of single frame heat transfer coefficient solar heat gain coefficient
  • 相关文献

参考文献4

  • 1[3]Technical Specification for Application of Architectural Glass JGJ113-2003.Beijing:China Architecture & Building Press,2003
  • 2[4]E.U.Finlayson,D.K.Arasteh,C.Huizenga,et al.WINDOW4.0:Documentation of Calculation Procedures.1993,7
  • 3[5]Robin Mitchell,Christian Kohler,Joe Klems,et al.WINDOW 6.1/THERM 6.1 Research Version User Manual 2006,9
  • 4[6]Carpenter S C,McGowan A G,Miller S R.Window Annual Energy Rating Systems:what they tell us About Residential Window design and Selection.ASHRAE Transactions,1998,104(10):806-813