摘要
对某加油站网架结构进行现场检测,发现该加油站网架的焊接球、杆件、支座等构件均存在多处安全问题,用SAP2000计算软件重新建立了有限元分析模型,进行了结构设计复核验算,并提出了该网架结构的加固改造建议。
Site detection was done for the rack structure of a fuel station.It was found that many problems were existing in its members,such as welding balls,supportsetc.Therefore recheck on the structural design was carried out using FEA model that was set up by SAP 2000.The suggestions on reforming the rack structure were also proposed.
出处
《工业建筑》
CSCD
北大核心
2008年第z1期1038-1039,1071,共3页
Industrial Construction
关键词
加油站
网架结构
验收
检测
加固
fuel station rack structure acceptance detection strengthen