期刊文献+

大型整体式浅圆贮煤筒仓局部堆煤作用有限元分析 被引量:5

Finite element analysis of whole huge squat silo under pressure of local region coal
原文传递
导出
摘要 整体式浅圆筒仓无温度缝,整个筒仓作为整体承受堆煤压力,局部堆煤压力为非平衡力,使筒仓产生不均匀的变形和位移,对筒仓顶部的网架结构、仓壁和基础造成不利影响.以某电厂大型整体式浅圆贮煤筒仓为例,使用大型通用有限元软件ANSYS进行三维非线性有限元分析,比较了在不同范围的局部堆煤压力作用下,筒仓仓壁、桩基础的响应特征,找出了最不利堆煤角度,对工程设计具有一定的指导意义. There is no temperature slot designed for whole huge squat silo,such leads silo to endure the pressure exerted by coal as a whole structure.Compared with full region coal,the pressure of local region coal is unbalance force which makes nonuniform deformation and displacement and has disadvantageous effect on the above grid structure,the silo wall and the pile foundation.Based on the background of the 120 meter diameter silo of Heyuan Power Station,the response of the silo wall and the pile foundation under ...
出处 《武汉大学学报(工学版)》 CAS CSCD 北大核心 2008年第S1期236-241,共6页 Engineering Journal of Wuhan University
关键词 火力发电 堆煤筒仓 堆煤压力 桩基础 理想弹塑性 fossil power generation coal silo pressure exerted by coal pile foundation perfect elastoplasticity
  • 相关文献

参考文献2

二级参考文献7

  • 1蒲维民.巨型筒仓温度作用的研究简介[J].煤矿设计,1996(3):35-36. 被引量:10
  • 2.国家标准.《钢筋混凝土筒仓设计规范》(GB50077.2003)[M].北京:中国计划出版社,2003..
  • 3GB50009—2001.国家标准.《建筑结构荷载规范》.[S].中华人民共和国建设部颁布,2001..
  • 4GB50077—2003钢筋混凝土筒仓设计规范[S].北京:中国建筑工业出版社,2004.
  • 5顾华孝译.筒仓理论与实践[R].北京:中国建筑工业出版社,1987.
  • 6JGJ/T22—98.钢筋混凝土薄壳结构设计规程[S].北京:中国建筑工业出版社,1998.
  • 7国际筒仓设计研究论文集[R].北京:煤炭工业出版社,1987.

共引文献38

同被引文献28

引证文献5

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...