基于关节机器人的人体脊柱生物力学试验装置设计 被引量:8

Joint-robotics-based design of biomechanics testing device on human spine
下载PDF
导出
摘要 目的建立机器人生物力学试验装置,进行人体脊柱标本生物力学实验研究。方法利用solidwork软件进行夹具设计,通过VisualC++6.0平台进行以太网套接字Socket编程实现PC机与机器人控制器之间的网络通信,读取机器人末端执行器的位置和旋转角度。PC机里面插入数据采集板读取力(力矩)传感器在三维空间中的力和力矩。位姿与力矩数据作为控制程序的输入数据,通过控制程序的处理,绘制出力-位移的二维曲线图,协助分析得出实验结果。结果开发并建立一套基于机器人的用于生物力学特性研究的实验装置,开发了相应的控制软件(力控制、位移控制、混合力/位移控制)及各类监控程序。结论设计出一套基于计算机控制的6自由度机器人全新实验装置,采用混合力/位移控制方法对实验对象进行加载,可以很好地测试脊柱功能单元各组织结构的功能和受力状态,很容易地确定脊柱退变和各类手术对脊柱功能单元各组织结构所承担负载的影响。 Objective To establish a biomechanical robot-based testing device to carry out biomechanical experiment of human spine.Method Use the solidwork software to design the fixture and adopt the socket programming to realize the network communications between PC and robot controller through Visual C + +6.0 platform, reading the position and rotation of the robot-end implementation.A data acquisition card is inserted inside the PC to read the force(torque) in three-dimensional space.The pose and torque data are pu...
出处 《医用生物力学》 CAS CSCD 2008年第6期446-453,共8页 Journal of Medical Biomechanics
基金 国家自然科学基金项目(30570458) 广东省自然科学基金资助(05006530)
关键词 生物力学 机器人 混合力/位移控制 Biomechanics Robot Hybrid force/displacement control
  • 相关文献

参考文献5

二级参考文献35

共引文献48

同被引文献58

  • 1卢海俊,朱青安,黄继锋,卢万发,吴增辉.一种脊柱运动的加载装置和测量方法[J].中国临床解剖学杂志,1993,11(2):147-148. 被引量:20
  • 2夏赣民,陈金龙,计欣华.数字标记点相关法在脊柱生物力学中的应用研究[J].中国生物医学工程学报,2005,24(5):554-559. 被引量:5
  • 3Panjabi MM. Biomechanical evaluation of spinal fixation de- vices: I. A conceptual framework [J ]. Spine, 1988,13 (10) : 1129-1134.
  • 4Wilke H J, Wenger K, Claes L. Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants [ J ]. Eur Spine J,1998, 7(2): 148-154.
  • 5Gerber M, Crawford NR, Chamberlain RH, et al. Biome- chanical assessment of anterior lumbar interbody fusion with an anterior lumbosacral fixation screw-plate: Compari- son to stand-alone anterior lumbar interbody fusion and an- terior lumbar interbody fusion with pedicle screws in an un- stable human cadaver model [ J ]. Spine, 2006,31 (6) : 762-768.
  • 6Cain CM, Schleicher P, Gerlach R, et aL A new stand-a- lone anterior lumbar interbody fusion device: Biomechanical comparison with established fixation techniques [J]. Spine, 2005,30 (23) : 2631-2636.
  • 7Lysack JT, Dickey JP, Dumas GA, et aL A continuous pure moment loading apparatus for biomechanical testing of multi-segment spine specimens [ J]. J Biomech, 2000, 33 (6) : 765-770.
  • 8Pflugmacher R, Schleicher P, Schaefer J, et aL Biome- chanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine [ J ]. Spine, 2004, 29(13) : 1413-1419.
  • 9Wilke H J, Krischak ST, Wenger KH, et aL Load-displace- ment properties of the thoracolumbar calf spine.. Experi- mental results and comparison to known human data [ J ]. Eur Spine J,1997,6(2) : 129-137.
  • 10Chang TS, Cheng CW, Wang CS, et al. A New multi-di- rection tester for evaluation of the spinal biomechanics [J]. J Med Bio Eng, 2008, 29(1) : 7-13.

引证文献8

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部