期刊文献+

Akreos Adapt亲水性丙烯酸酯与硅凝胶人工晶状体临床应用比较 被引量:1

Comparison of Akreos Adapt and SoFlex silicone intraocular lens
下载PDF
导出
摘要 目的比较亲水性丙烯酸酯人工晶状体(intraocularlens,IOL)与硅凝胶IOL的临床效果。方法对209例(209眼)白内障患者行超声乳化吸除联合人工晶状体植入术,A组(93眼)植入亲水性丙烯酸酯Akreos Adapt IOL,B组(116眼)植入SoFlex SE三体型硅凝胶IOL。观察两组IOL的植入性能、术中并发症、术后视力、前房反应和IOL表面色素沉着、IOL位置、后囊混浊程度,随访时间>12个月。结果术后最佳矫正视力两组差异无统计学意义(χ2=0.28,P>0.05)。两组前房闪辉均较轻(+^++)。IOL表面沉积物的发生率:A组3眼(占3.26%),B组13眼(占11.21%),差异有统计学意义(P<0.05)。术中并发症:Akreos Adapt组无异常情况,SoFlexSE三体型硅凝胶组发生IOL襻变形2例,襻脱落1例。术后并发症:Akreos adapt组发生1例IOL脱位入玻璃体腔中,该患者术中后囊破裂,IOL植入睫状沟内,于术后第1个月IOL脱入玻璃体腔中,其余植入囊袋内的Akreos Adapt IOL未发生移位,居中性良好。SoFlex SE组发生1例IOL襻移位入前房内,1例IOL光学部移位形成瞳孔区夹持。后囊混浊程度:A组(占9.68%)与B组(占15.52%)间差异无统计学意义(P>0.05)。结论与硅凝胶IOL相比,Akreos Adapt IOL植入操作更容易,并发症更少,炎症反应更低,且具有良好的居中性和稳定性,临床应用疗效满意。 Objective To compare the clinical outcome of hy-drophilic acrylic(Akreos Adapt)intraocular lens(IOL)and silicone(SE)IOL.Methods Two hundred and nine patients(209 eyes)with cataract that underwent phaco with implantation of a foldable Akreos Adapt IOL(93 eyes,group A)and a foldable SoFlex SE IOL(116 eyes,group B).Preoperative and postoperative uncorrected visual acuity and best corrected visual acuity,intraocular pressure(IOP),inflammation and complications were examined after 12 months.Results There was no ...
出处 《眼视光学杂志》 2008年第6期416-418,共3页 Chinese Journal of Optometry & Ophthalmology
关键词 晶体 人工 丙烯酸酯 硅凝胶 lens intraocular Hydrophilic Acrylic silicone
  • 相关文献

参考文献6

二级参考文献41

  • 1陈佩卿,姚克.水凝胶人工晶状体混浊一例[J].中华眼科杂志,2004,40(8):571-572. 被引量:6
  • 2[1]Assia EI,Legler UF,Merrill C,et al.Clinicopathologic study of the effect of radial tears and loop fixation on intraocular lens decentration.Ophthalmology,1993; 100(2):153-158.
  • 3[2]Rufer F,Schroder A,Arvani MK,et al.Central and eripheral corneal pachymetry standard evaluation with the Pentacam system.Klin Monatsbl Augenheilkd,2005;222(2):117-122.
  • 4[3]Adamsons I,Taylor KI,Enger C,et al.A new method for documenting lens opacities.Am J Ophthalmol,1991; 111(1):65-70.
  • 5[4]Barkana Y,Gerber Y,Elbaz U,et al.Central corneal thickness measurement with the Pentacam Scheimpflug system,optical low-coherence reflectometry pachymeter,and ultrasound pachymetry.J Cataract Refract Surg,2005; 31 (9):1729-1735.
  • 6[5]Hansen SO,Tetz MR,Solomon KD,et al.Decentration of flexible loop posterior chamber intraocular lenses in a series of 222 postmortem eyes.Ophthalmology,1988; 95(3):344-349.
  • 7[6]Guyton DL,Uozato H,Wisnicki HJ.Rapid determination of intraocular lens tilt and decentration through the undilated pupil.Ophthalmology,1990; 97 (10):1259-1264.
  • 8[7]Caporossi A,Casprini F,Tosi GM,et al.Preliminary results of cataract extraction with implantation of a singlepiece AcrySof intraocular lens.J Cataract Refract Surg,2002; 28 (4):652-655.
  • 9[8]Kugelberg U,Zetterstrom C,Lundgren B,et al.Ocular growth in newborn rabbit eyes implanted with a poly (methyl methacrylate) or silicone intraocular lens.J Cataract Refract Surg,1997; 23 (1):629-634.
  • 10[9]Vasavada A,Singh R.Relationship between lens and capsular bag size.J Cataract Refract Surg,1998 ;24(4):547-551.

共引文献18

同被引文献14

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部