摘要 基于CFD软件和自然通风湿式冷却塔相关理论,对气流运动采用标准k-ε湍流模型,喷淋区和雨区采用离散相模型计算,对填料区建立了基于Poppe理论的数值求解模型。并通过编译自定义源项函数,实现其在FLUENT中的求解。基于该模型,在不考虑自然风情况下,对某300MW机组自然通风冷却塔的气水流动与热质交换进行数值模拟。分析了淋水密度、进塔水温和环境条件对冷却塔热力特性的影响。计算结果表明:基于CFD软件的冷却塔数值求解模型有很好的适用性,淋水密度和环境条件对出塔水温影响很大。 The software FLUENT and related theory are applied to study the heat and mass transfer as well as the air-water flow inside a natural draft wet cooling tower.The standard k-ε turbulence model is used to calculate the air flow and the discrete phase model is applied to simulate the spray and raining zone.A numerical model based on Poppe s theory for analyzing the performance of filling material is established.By using the user-defined source terms to represent the heat and mass transfer the model can solved ...
出处 《水利学报》 EI CSCD 北大核心 2009年第2期208-213,共6页 Journal of Hydraulic Engineering
关键词 冷却塔 热力特性 离散相 数值模拟 cooling water tower thermal performance discrete phase numerical simulation
  • 相关文献

参考文献2

二级参考文献17

  • 1赵振国,石金铃,陈仙松,李志悌.逆流式自然通风冷却塔通风阻力的研究[J].水动力学研究与进展(A辑),1993,8(4):462-474. 被引量:11
  • 2毛献忠.逆流式自然通风冷却塔流场及热质交换的数值模拟[J].河口与海岸工程,1994(1):28-34. 被引量:1
  • 3赵顺安.逆流式自然通风冷却塔塔内气流场及换热的数值模拟.水利水电科学研究院科学研究论文集(第33集)[M].北京:水利出版社,1990,11..
  • 4滕新军 石金玲.天津某发电厂2号冷却塔测试报告[M].中国水利水电科学研究院冷却水研究所,1997,8..
  • 5石金玲 滕新军.山东某电厂六号塔测试报告[M].中国水利水电科学研究院冷却水研究所,1998,9..
  • 6陈仙松.湿式自然通风冷却塔热态数值模拟[R].北京:水利水电科学研究院,1993..
  • 7赵顺安 陆振铎.十二种逆流塔填料测试报告[R].北京:水利水电科学研究院,1992..
  • 8赵顺安.逆流式自然通风冷却塔塔气流场及换热的数值模拟[A]..水利水电科学研究院论文集(第33集)[C].北京:水利水电出版社,1990..
  • 9许玉林 等.邯峰电厂冷却塔虹吸式配水模型试验报告[R].北京:中国水利水电科学研究院,1999..
  • 10赵顺安.山西阳城电厂三号冷却塔测试报告[R].北京:中国水利水电科学研究院,2002.9.