期刊文献+

松质骨一维动电效应分析 被引量:1

One-Demensional Electrokinetic Effect Analysis of Cancellous Bone
下载PDF
导出
摘要 通过对松质骨结构特征和力学行为的实验观察 ,引入基于混合物理论的现代两相多孔介质弹性模型和动电效应模型来描述松质骨固体骨质变形、孔间骨髓流动以及骨内流动电位间的耦合效应。采用Laplace变换技术得到了松质骨围限压缩下流动电位分布的解析结果。结果表明 ,由于在外界作用下松质骨骨小梁结构产生变形 ,引起孔间骨髓流动 ,从而使带电粒子在孔隙间运动 。 Based on experimental observations for the cancellous bone structure and its mechanics behavior, a biphasic porous medium model which is based on the mixture theory and a electrokinetic phenomena model are introduced to describe the coupling among the distortion, fluid flow and streaming potential in cancellous bone. By using Laplace transform technique, the one-demensional analytical solution under dynamic load of streaming potential distributing is obtained for cancellous bone. The computational results show that because of the distortion of concellous bone the marrow's flow is arised, then the electriferous particle moves in the porous and the streaming potential appears.
机构地区 重庆大学 汕头大学
出处 《重庆大学学报(自然科学版)》 EI CAS CSCD 2000年第z1期181-183,192,共4页 Journal of Chongqing University
关键词 松质骨 多孔介质 流动电位 cancellous bone porous medium streaming potential
  • 相关文献

参考文献5

  • 1[1]TONY M, KEAVENY,WILLSON C, HAYERS. A 20-Year Perspective on the Mechanical properties of Trabecular bone [J]. J Biomech Engng, 1993, 115: 534-542.
  • 2[2]FUKADA E, YASUDA I. On the piezoelectric effect of bone[J]. J Phys Soc Jan, 1957, 12:1 158-1 162.
  • 3[3]ANDERSON J, ERIKSSON C. Electrical properties of wet collagen[J]. Nature, 1968,218(4):166-168.
  • 4侯振德,高瑞亭.骨的力电性质[J].力学进展,1995,25(1):85-101. 被引量:28
  • 5[5]SALZSTEIN R A. Electromechanical potentials in carticul bone-I[J]. A continuum approach. J Biomech 1987, 106:261-270.

共引文献27

同被引文献24

  • 1李德源,陈海斌,王正国.基于两相多孔介质模型的骨组织力学响应数值分析[J].生物医学工程学杂志,2004,21(3):381-386. 被引量:3
  • 2王璠.骨质疏松与力学[J].力学与实践,2004,26(3):94-95. 被引量:7
  • 3王颖坚.松质骨的细观力学研究评述[J].力学进展,1996,26(3):416-423. 被引量:22
  • 4Keaveny TM, Hayes WC. A 20-year perspective on the mechanical properties of trabecular bone [ J]. J Biomech Eng, 1993, 115(4B) : 534-542.
  • 5Yasuda I. Fundamental aspects of fracture treatment [ J]. J K Yoto Med Soc, 1953, 44: 396-406.
  • 6Uklejewski R. Initial piezoelectric polarization of cortical bone matrix as a determinant of the electrokinetic potential Zeta of that bone osteonic lamella as mechanoelectret [ J]. J Biomech, 1994, 27(7) : 991-992.
  • 7Gross D, Williams WS. Streaming potentials and the elec- tromechanical response of physiologically moist bone [ J ]. J Biomech, 1982, 15(4):277-295.
  • 8Guzelsu N, Walsh WR. Streaming potential of intact wet bone [J]. J Biomech, 1990, 23(7) : 673-685.
  • 9Kowalchuk RM, Pollack SR, Corcoran TA. Zeta potential of bone from particle electrophoresis: Solution composition and kinetic effects [ J ]. J Biomed Mater Res, 1995, :29 ( 1 ) : 47-57.
  • 10Silva CC, Pinheiro AG, Thomazini D, et aL Effect of the pH on the piezoelectric properties of collagen films[ J ]. Mater Sci Eng, 2001,83(1-3) : 165-172.

引证文献1