叙述了冲击片点火管的设计原则 ,优化了结构及设计参数 ,并进行了性能试验。试验结果表明 :圆柱形冲击片点火管有较小的电感和电阻 ,发火阈值能量较低 ,是一种安全点火管 。
This paper describes the design principle of the slapper igniter with optimal structures and parameters. Performance tests have been conducted, and the results of the tests indicated that the cylinder slapper igniter has lower inductance, lower impedance and lower firing energy thresholds. It is substantially a safety igniter, suitable for linear ignition system.