期刊文献+

基于TDLAS技术1.65μm附近乙烷分子高分辨吸收光谱测量 被引量:3

Measurement of Ethane Spectrum with High Resolution near 1.65μm Based on TDLAS
下载PDF
导出
摘要 基于可调谐半导体激光光谱(TDLAS)技术,结合实验室自制程长可达50 m的Herriot池,使用波长计对乙烷吸收谱线进行了准确定标,并根据记录的光谱数据,精确测量了6039~6054 cm^(-1)波段内71条乙烷分子的谱线(中心位置及谱线强度),最小可探测谱线吸收强度为10^(-25)cm^(-1)/(molecule·cm^(-2)),对结果及误差进行了详细分析,为进一步研究天然气提供了重要参考。 Based on tunable diode laser absorption spectroscopy(TDLAS) technology,combining a Herriot cell with optical length of 50 m,using a wave-length-meter to scale the positions of the lines,the positions and intensities of 71 ethane lines between 6039 cm^(-1) and 6054 cm^(-1) are precisely measured,and the minimum detection absorption intensity reaches 10^(-25) cm^(-1)/(molecule.cm^(-2)).Results and errors are analyzed in detail, which is very useful to carry on research of natural gas in further
出处 《大气与环境光学学报》 CAS 2009年第1期38-45,共8页 Journal of Atmospheric and Environmental Optics
关键词 可调谐半导体激光光谱技术 Herriot池 乙烷 Voigt拟合 tunable diode laser absorption spectroscopy Herriot cell ethane Voigt fitting
  • 相关文献

参考文献12

  • 1[1]Bomse D S.Diode laser finding trace gases in the lab and the plant[J].Photonics Spectra,1995,6:88-94.
  • 2[2]Nelson D D,Zahniser M S,McManus J B,et al.A tunable diode laser system for the remote sensing of on-road vehicle emissions[J].Appl.Phys.B,1998,67:433-441.
  • 3[3]Cooper D E,Martinelli R U.Near-infrared diode lasers monitor molecular species[J].Laser Focus World,1992,11:133-146.
  • 4[4]Koch J,Zybin A,Niemax K.Element-selective trace detection of toxic species in environmen-tal samples using chromatographic techniques and derivative diode laser absorption spectroscopy[J].Appl.Phys.B,1998,67:475-479.
  • 5[5]Adam H,Bauer J,Thornton E.Greenhouse gas emissions and reduction studies using a portable TDL gas monitor[R].Boreal Laser Inc,1999.
  • 6[7]Zaatar Y,Bechara J,Khoury A,et al.Diode laser sensor for process control and environmental mon-itoring[J].Appl.Energy,2000,65:107-113.
  • 7[8]Uhl R,Reinhardt T,Haas U,et al.Gas leak de-tection by diode laser absorption spectrometry[J].Spectrochimica Acta Part B,1999,54:1737-1741.
  • 8[9]Chizhevskii E G,Ponurovskii Y Y,Selivanov Y G,et al.TDL based analyzer of the 13C/12C ratio in exhaled CO2 and it's clinical applications[C].2nd Int.Conf.on Tunable Diode Laser Spectroscopy,1998,6-10.
  • 9[10]Oh D B,Stanton A C.Application of tun-able diode laser spectroscopy in combustion,at-mospheric and material growth monitoring[C].SPIE,1998,3285:163-168.
  • 10[11]Corsi C,Gabrysch M,Modugno G,et al.High sensitivity trace gas monitoring for medical and environmental applications using semiconductor diode laser[C].SPIE,1998,3423:218-223.

同被引文献76

引证文献3

二级引证文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部