The beam horizontal orbit at Hefei Light Source(HLS)was drifting all along while the storage ring was operating.To study this phenomenon,the displacement and the temperature variation of the BPM chamber were measured.By analyzing the measurement results,the main reason that explained the drifting phenomenon was found. The vacuum chamber following the dipole magnets was heated by the synchrotron light,which caused the increasing of the chamber surface temperature.The variation of the chamber temperature was the main reason why the BPM chamber held the horizontal displacement.To suppress the orbit drifting,a compensation method of BPM movement was proposed and its experimental results were given.
合肥光源电子储存环的束流水平轨道存在缓慢漂移现象,本文针对这一现象进行了束流位置检测器(BPM)真空室形变、位移和温度等参数的测量.通过这些测量,分析了BPM真空室的形变、位移、温度以及束流轨道漂移与束流流强的关系,对束流水平轨道的漂移现象做出合理的解释,即导致轨道水平漂移的主要原因是同步光热效应导致BPM真空室水平移动,提出了采用补偿方法对BPM的轨道测量值进行实时修正,从而提高了慢速轨道反馈系统有效性.
基金
国家自然科学基金项目(10675118)