摘要
介绍了采用多级压缩的离心空压机的级间冷却时出现的冷凝水的分离和排放问题,提出了排放管路的选择及操作管理应注意的问题,并采取了相应的改进措施。
This paper introduces the separation and discharge problem of condensate water when the cooling between stages is carried out by using centrifugal air-compressor with multi-stage compression. The selection for discharge pipe is pointed out and the attentions should be paid to operation and management. The corresponding improvement is adopted.
出处
《风机技术》
2008年第2期83-84,共2页
Chinese Journal of Turbomachinery
关键词
离心式压缩机
冷却器
排放管路
改进
centrifugal compressor
cooler
discharger pipe
improvement