期刊文献+

Composite insulators and their aging: An overview 被引量:4

Composite insulators and their aging: An overview
原文传递
导出
摘要 The aging (biological deterioration) is a major problem of composite insulators now-a-days. The main thing in aging is to predict how, when and with what speed it occurs and under what conditions it can lead to failure and what overall average expected life of a composite insulator is. For this a lot of researches have been done. This review summarizes the methods of artificial field testing (aging), natural testing, standards the developed for aging, techniques of analysis, results achieved until now about various parameters from various locations, handling guidelines and a conclusion on what is further needed. The aging (biological deterioration) is a major problem of composite insulators now-a-days. The main thing in aging is to predict how, when and with what speed it occurs and under what conditions it can lead to failure and what overall average expected life of a composite insulator is. For this a lot of researches have been done. This review summarizes the methods of artificial field testing (aging), natural testing, standards the developed for aging, techniques of analysis, results achieved until now about various parameters from various locations, handling guidelines and a conclusion on what is further needed.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2007年第6期697-713,共17页 中国科学(技术科学英文版)
关键词 POLYMERIC insulators aging composite SEM polymeric insulators, aging, composite, SEM
  • 相关文献

参考文献36

  • 1[1]Reynders J P,Jandrell I R,Reynders S M.Surface aging mechanisms and their relationship to service performance of silicon rubber insulation.In:10th International Symposium on High Voltage Engineering,London,UK,22-27 August,1999.54-58
  • 2[2]Gorur R S,Cherney E A,Burnham J T.Outdoor Insulators.Phoenix:Ravi S.Gorur Inc.,1999
  • 3[3]Phillips A.Ceramic vs.Polymer (Non-Ceramic) Insulators.EPRI.March 2002
  • 4[4]Hillborg H,Gedde U W.Hydrophobicity recovery of poly dimethyl siloxane after exposure to corona discharges.Polymer,1998,39(10):1991-1998
  • 5[5]Sharma K.Polymer insulators,available on-line at http://www.aset.ab.ca/pdffiles/article3.pdf
  • 6[6]Gerdinaud F M,Kurrat B M.State estimate of mineral filled insulators with loss factor measurement.Institute for High Voltage Technology and Electric Power System,Technical University of Braunschweigh,Germany
  • 7[7]Multistress Aging of Polymeric Insulators in Various Environmental Conditions.www.east.asu.edu/ctas/multistress/Papers/nsf-2-5.pdf
  • 8[8]Sampe T,Ito A,Hirayama T,et al.Department of Electrical Engineering,Chubu University,Japan.275 kV full scale outdoor exposure test result of RTV silicon rubber coated polymeric insulator.In:The 8th Korea-Japan Joint Symposium on Electrical Discharge and High Voltage Engineering (2003 K-J Symposium on ED & HVE),Chongqing,China,Nov.2003
  • 9[9]Jellinek H H G.Degradation of Vinyl Polymers.New York:Academic Press Inc.Publishers,1955
  • 10[10]Sarathi R,Chandrasekar S,Giri V S,et al.Analysis of surface degradation of high density polyethylene material due to tracking.Bull Mater Sci,2004,27(3):251-262

同被引文献15