期刊文献+

ORBSCAN-Ⅱ角膜地形图在眼科中的应用

下载PDF
导出
摘要   角膜作为人眼屈光系统的重要组成部分,其地形、屈光力和厚度的准确测量直接决定着屈光手术的设计和角膜疾病的诊断.通常角膜地形图仪测量角膜前表面的地形,是角膜屈光力的主要来源,近年的研究表明角膜后表面的形状同样也影响着角膜的屈光力[1].角膜的厚度影响着内皮细胞层的屏障和泵功能,它的准确测量对于角膜疾病的诊断和避免屈光手术术后圆锥角膜的发生起着重要的作用[2].……
作者 潘红飙
出处 《实用防盲技术》 2007年第4期40-41,44,共3页 Journal of Practical Preventing Blind
  • 相关文献

参考文献23

  • 1[1]Rao SK,Padmanabhan P.Understanding corneal topography.Curr Opin Ophthalmol,2000,11:248-259.
  • 2[2]Liu Z,Huang AJ,Pflugfelder SC.Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.Br J Ophthalmol,1999,83:774-778.
  • 3[3]Banu CC,Bozkurt SA.Orbscan corneal topography system in evaluating the anterior stucture of the human eye.Cornea,2003,22:118-121.
  • 4张艳玲,施明光.Orbscan角膜地形图系统的临床应用[J].中国中医眼科杂志,2004,14(2):114-117. 被引量:4
  • 5刘祖国,谢玉环,张梅.正常人角膜前后表面地形及全角膜厚度的研究[J].中华眼科杂志,2001,37(2):125-128. 被引量:32
  • 6倪海龙,陈彬彬,王勤美.角膜后表面屈光力理论计算值与Orbscan测量值的比较[J].眼科研究,2004,22(6):647-649. 被引量:2
  • 7[7]Gherghel D,Hosking SL,Mantry S,Banerjee S,Naroo SA,Shah S.Corneal pachymetry in normal and keratoconic eyes:Orbscan 2 versus ultrasound.J Cataract Refract Surg,2004,30:1272-1277.
  • 8[8]Buehl W,Stojanac D,Sacu S,Drexler W,Findl O.Comparison of three methods of measuring Corneal thickenss and anterior chamber depth.Am J Ophthal,2006,141:7-12.
  • 9[9]Suzuki S,Oshika T,Oki K,Sakabe I,Iwase A,Amano S,Araie M.Corneal thickenss measurements:Scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry.J Cataract Refract Surg,2003,29:1313-1318.
  • 10[10]Gonzalez-Meijome JM,Cervifio A,Yebra-Pimentel E,Parafita MA.Central and peripheral corneal thickness measurement with Orbscan 2 and topographical ultrasound pachymetry.J Cataract Refract Surg,2003,29:125-132.

二级参考文献46

  • 1Iskander NG, Anderson PE, Peters NT, et al. Accuracy of orbscan pachymetry measurements and DGH ultrasound pachymetry in primary laser in situ keratomileusis and Lasik enhancement procedures [ J]. J Cataract Refract Surg,2001,27: 681 ~ 685
  • 2Yaylali V, Kaufman SC, Thompson HW. Corneal thickness measures with orbscan topography system and ultrasomic pachymetry[J] .J Cataract Refract Surg, 1997,23:1345 - 1350
  • 3Alessio G, Boscia F, La Tegola M G, et al. Corneal interactive progranamed topographic ablation customized photorefractive keratectomy for correction of postkeratoplasty astigmatism [J] . Ophthalmology, 2001,108 (11): 2029-2037.
  • 4Chakrabarti H S, Craig J P, Brahma A, et al. Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes [J] .J Cataract Refract Surg,2001, 27 (11): 1823-1828.
  • 5Liu Z, Huang A J, Pflugfelder S C, et al. Evaluation of corneal thickness and topography in normal eyes using the Orbscan comeal topography system [J] .BrJ Ophthalmol, 1999, 83: 774-778.
  • 6Alessio G, Boscia F, La Tegola M G, et al. Topography-driven photorefractive keratectomy: results of corneal interactive programmed topographic ablation software [J] .Ophthalmology, 2000, 107 (8): 1578-1587.
  • 7Alessio G, Boscia F, La Tegola M G, et al. Topography-driven exeimer laser for the retreatment of decentralized myopic photorefractive keratectomy [J] .Ophthalmology, 2001, 108 (9): 1695-1703.
  • 8Wang Z, Chen J, Yang B.Posterior corneal surface topographic changes after Laser In Situ Keratomileusis are related to residual comeal bed thickness [J] .Ophthalmology, 1999, 106 (2): 406-409.
  • 9Kamiya K, Oshika T. Corneal forward shift after excimer laser keratorefractive surgery [J] . Semin Ophthalmol, 2003, 18 (1): 17-22.
  • 10Lee D H, See S, Jeeng K W, et al. Early spatial changes in the posterior comeal surface after laser in situ keratomileusis [J] . J Cataract Refract Surg, 2003, 29 (4): 778-784.

共引文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部