分析了双轴四级离心式压缩机轴头泵频繁发生故障的原因,提出并实施了相应的改造措施,取得了满意的效果。
This paper has analyzed the reason of the fault frequently occurred on shaft head pump of Ⅳ stage centrifugal compressor with double - axis and pointed out the relevant transformation measures. And the satisfied effect is obtained.