期刊文献+

板间距对花板换热器综合性能影响的实验研究

Influnce of Distance Between Two Flower Baffles on Overall Performance of the Heat Exchanger
下载PDF
导出
摘要 介绍了花板管壳式换热器的结构及设计思想。通过实验研究表明,在相同壳程流量下,板间距为134mm时,换热器的传热系数K是板间距为163mm、147mm、123mm时的102%~110%;壳程压降Δp则约为板间距为163mm、147mm、123mm时的97%~105%;而综合性能K/Δp比板间距为163mm、147mm、123mm时高3%~9%,本实验认为最佳板间距存在于134mm~147mm之间。 The structure and design philosophy of the flower baffle heat exchanger are presented in this paper.Through the experimental study,with same shell side flow,when the distance between two flower baffles is 134mm,the heat transfer coefficient K is 102%-110% times of that with distance between is 163mm,147mm or 123mm.The shell side pressure drop of flower baffle heat exchanger with a distance between two flower baffles of 134mm is 97%-105% times of that while the distance between is 163mm,147mm or 123mm.The ov...
出处 《煤化工》 CAS 2009年第5期29-31,共3页 Coal Chemical Industry
基金 广东省科技计划项目资助 项目编号(No.2005A10501001)
关键词 花板换热器 板间距 实验研究 flower baffle heat exchanger distance between two flower baffles experimental study
  • 相关文献

参考文献4

二级参考文献24

  • 1王良,罗来勤,王秋旺,曾敏,陶文铨.螺旋折流板换热器中阻流板对换热及沿程压降的影响[J].工程热物理学报,2001,22(S1):173-176. 被引量:41
  • 2郭春福,高绪镇,李志安.管壳式换热器传热强化技术进展[J].辽宁化工,2004,33(7):399-402. 被引量:7
  • 3王定标,向飒,魏新利,郭茶秀,刘宏.杆式支撑换热器传热与流阻性能的实验研究[J].石油机械,2005,33(9):1-5. 被引量:1
  • 4张平亮.新型高效换热器的技术进展及其应用[J].压力容器,1997,14(2):56-62. 被引量:29
  • 5[1]Stehlik P, Wadekar V. Different strategies to improve industrial heat exchanger[J]. Heat Transfer Engineering, 2002, 23(6): 36-48.
  • 6[3]施林德尔 E U. 换热器设计手册:第3卷[Z]. 马庆芳,马重芳,等译. 北京:机械工业出版社, 1988.
  • 7[4]Li H D, Kottke V. Effect of baffle spacing on pressure drop and local heat transfer in shell-and-tube heat exchangers for staggered tube arrangement[J]. Int J Heat Mass Transfer, 1998, 41(1): 1 303-1 311.
  • 8[5]Li H D, Kottke V. Visualization and determination of local heat transfer coefficients in shell-and-tube heat exchangers for staggered tube arrangement by mass transfer measurements[J]. Experimental Thermal and Fluid Science, 1998(17): 210-216.
  • 9[7]Reppich M, Zagermann S. A new design method for segmentally baffled heat exchangers[J]. Computers Chem Eng, 1995(19): 137-142.
  • 10[8]Lutcha J, Nemcansky J. Performance improvement of tubular heat exchangers by helical baffles[J]. Trans IChME, 1990, 68(A): 263-270.

共引文献101