摘要
针对定电位电解法测定烟道气SO2过程中所存在的湿度、负压,以及NO2、CO等气体的干扰问题,依据现场监测条件,运用模拟试验方法,分析了湿度、负压和干扰气体产生干扰的原因以及对SO2测定结果的影响,探讨了消除湿度、负压和干扰气体影响的方法,并对定电位电解法测定烟道气SO2过程中存在的问题提出了具体的对策和建议。
The interference of humidity,negative pressure,and the gases,such as NO2 and CO were discussed on the measurement of sulfur dioxide in flue gases by using Fixed-Potential Electrolysis Method.Based on the in-situ monitoring,the simulation test was introduced to analyse their causes and impacts.Methods for eliminating the interference of the humidity,negative pressure and gases were discussed,the countermeasures and advice were put forward for improving the measurement of sulfur dioxide in flue gases by using...
出处
《城市环境与城市生态》
CAS
CSCD
2009年第4期41-43,47,共4页
Urban Environment & Urban Ecology
关键词
二氧化硫
定电位电解法
烟道气
湿度
负压
干扰气体
干扰性能测试方法
sulfur dioxide
fixed-potential electrolysis method
flue gases
humidity negative pressure
interference gases
interference performance test