摘要
针对国产200MW机组普遍存在的局部负荷区域运行稳定性差等问题,分析了凸轮配汽机构对负荷摆动及机组效率的影响,并提出了改造方案,现场应用后取得了良好效果,具有一定的推广价值。
According to the low stability in part section of homemade 200MW turbine,analyses the influence of steam distribution on load swing and turbine efficiency,puts forward the measures to reform.After application,it gets better results.It has the great value to popularize.
出处
《沈阳工程学院学报(自然科学版)》
2003年第2期14-16,共3页
Journal of Shenyang Institute of Engineering:Natural Science
关键词
200
MW汽轮机
配汽机构
稳定性
效率
200MW turbine
steam distribution mechanism
stability
efficiency