期刊文献+

EXPERIMENTAL RESEARCH ON EVALUATING STRUCTURE DAMAGE WITH PIEZOELECTRIC DYNAMIC IMPEDANCE 被引量:2

EXPERIMENTAL RESEARCH ON EVALUATING STRUCTURE DAMAGE WITH PIEZOELECTRIC DYNAMIC IMPEDANCE
下载PDF
导出
摘要 A dynamic impedance-based structural health monitoring technique isintroduced. According to the direct and the converse piezoelectric property of piezoelectricmaterials, the piezoceramic (PZT) can be used as an actuator and a sensor synchronously. If damageslike cracks, holes, debonding or loose connections are presented in the structure, the physicalvariations of the structure will cause the mechanical impedance modified. On the basis ofintroducing the principle and the theory, the experiment and the analysis on some damages of thestructure are studied by means of the dynamic impedance technique. On the view of experiment, kindsof structural damages are evaluated by the information of dynamic impedance in order to validate thefeasibility of the method. A dynamic impedance-based structural health monitoring technique isintroduced. According to the direct and the converse piezoelectric property of piezoelectricmaterials, the piezoceramic (PZT) can be used as an actuator and a sensor synchronously. If damageslike cracks, holes, debonding or loose connections are presented in the structure, the physicalvariations of the structure will cause the mechanical impedance modified. On the basis ofintroducing the principle and the theory, the experiment and the analysis on some damages of thestructure are studied by means of the dynamic impedance technique. On the view of experiment, kindsof structural damages are evaluated by the information of dynamic impedance in order to validate thefeasibility of the method.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第3期204-208,共5页 中国机械工程学报(英文版)
基金 This project is supported by Foundation of Study Abroad Returnee,Ministry of Education of China(No.2000-367) and Open Foundation of the State Key Laboratory of VSN,Shanghai Jiaotong University,China(No.VSN-2001-03).
关键词 Dynamic impedance PZT Structural damage Health monitoring Dynamic impedance PZT Structural damage Health monitoring
  • 相关文献

参考文献8

  • 1[1]Lalande F, Rogers C A. High-frequency analysis for NDE of compliex precision parts. In:Proc. of SPIE Smart and Materials, San Diego, C A, 1996
  • 2[2]Chonan S, Jiang Z W. Development of a paplation sensor for detection of prostatic cancer and hypertrophy. Int. J. Applied Electromagnetrics and Mechanical, 1998, 16(9):25~39
  • 3[3]Giurgiutiu V, Rogers C A. Electro-mechanical(E/M) impedance method for structural health monitoring and non-destructive evaluation. In:Proc. of SPIE Nondestructive Evaluation Techniques for Aging Infrastructure & Manufacturing, Scottsdale, A Z, 1996, 2 946:211~218
  • 4[4]Frederic Lalande , Rogers C A. Qualitative nondestructive evaluation research at CIMSS. In:Proc. the 3rd Int. Conf. on Intelligent Materials, Lyon, France, 1996
  • 5[5]Gyuhae Park, Kazuhisa Kabeya, Harley H, et al. Impedance-based structural health monitoring for varying applications. JSME Int. Journal, 1999, Series A, 42(2):249~258
  • 6[6]Liang C, Sun F P, Rogers C A, et al. Coupled electro-mechanical analysis of adaptive material systems. J. of Intelligent Material Systems and Structures, 19978(8):335~343
  • 7[7]Wang X M, Claus Ehlers, Manfred Neitzel. Investigation on the dynamic actuation of piezoelectric patches bonded on a beam. In:Proc. of the Seventh International Conference on Adaptive Structures, Rome, Italy, 1996:425~434
  • 8[8]Liang C, Sun F P, Rogers C A, et al. Electro-mechanical impedance modeling of active material systems. Smart Material Structures, 1996, 5(5):171~186

同被引文献9

引证文献2

二级引证文献4