期刊文献+

200MW汽轮机的大负荷滑停运行

High load sliding shut-down operation of 200MW steam turbine
下载PDF
导出
摘要 针对200MW汽轮机在常规滑参数停机时,在低负荷滑降时汽缸温度比较高,滑停时间较长,锅炉低负荷时须投油稳燃等问题,通过对大负荷滑参数停机的技术分析及与常规滑参数停机的比较,得出了采用大负荷滑参数停机方法,成功的解决了常规滑参数停机中存在的问题。 During operation of 200MW steam turbine, there are some problems such as high temperature in cylinder during low load sliding shut down, longer sliding shut down time, and higher cost of steady combustion. By analyzing method of high load and sliding shut down and comparing it with method of conventional load and sliding shut down, the paper concludes that high load sliding shut down operation can successfully resolve the problem in conventional shut down operation.
出处 《长春工程学院学报(自然科学版)》 2003年第2期54-56,共3页 Journal of Changchun Institute of Technology:Natural Sciences Edition
关键词 汽轮机 滑参数停机 大负荷滑参数停机 steam turbine sliding shut down high load sliding shut down
  • 相关文献

参考文献2

  • 1[1]杨世铭.传热学(第2版)[M].北京:高等教育出版社,1990.
  • 2[2]朱安仁,齐复东,等.20万千瓦汽轮机的结构及运行[M].北京:水利电力版社,1990.