摘要 全面分析了凝汽器铜管氨腐蚀机理及其影响因素,并探讨一定的防护措施,指出采用双面强化传热不锈钢管是凝汽器无铜化改造的最佳选择.基于此,利用水平式单管传热与流阻特性通用试验装置,以水蒸汽、水为工质,对2种钢质双面强化传热管--螺旋槽管和新近研制出的内螺旋外棘齿管进行了冷凝换热特性和流体动力学特性试验研究.依据试验结果,对采用双面强化传热不锈钢管的凝汽器改造方案进行了经济效益分析.基础试验结果表明:螺旋槽管的总传热系数要比光滑管提高10%~17%,内螺旋外棘齿管的总传热系数好于螺旋槽管,是光滑管的1.22~1.28倍;经济分析表明:采用不锈钢螺旋槽管的改造方案比不锈钢光滑管具有更好的综合技术经济性能. This paper analyzes comprehensively the mechanism of condenser copper pipe corrosion and the influencing fac-tors,and presents some prevention measurement and methods.The stainless steel tube with double side enhancement heat transfer is proved to be the best choice for condenser reconstruction in non-copper issue.Based on this,using a general steam condensation testing equipment only for horizontal single tube,with water vapor and water as working fluid,on two types of steel tube with double side enhancement heat transfer,namely,spirally fluted tube ratchet tube with internal spiral groove(RISG tube) which was developed recently,a set of experimental tests are performed to investigate the characteris-tics of heat transfer and hydromechanics.According to the experimental results,economic benefit analysis is carried out for condenser reconstruction scheme with 2side enhancement tube as heat transfer tube.The experimental results show that the overall heat transfer coefficient of spirally fluted tube is improved by 10% to 17%,and that the RISG tube is better than spirally fluted tube.Its enhance value is 1.22 to 1.28 compared with smooth tube.The economic benefit analysis results show that the scheme with 2 side enhancement tube as heat transfer tube has better integration technology economy perfor-mance than that with only stainless steel smooth tube as heat transfer tube.
出处 《华电技术》 CAS 2006年第9期40-45,共6页 HUADIAN TECHNOLOGY
基金 广东省科技计划项目(2KM00905G)资助
关键词 凝汽器 氨腐蚀 螺旋槽管 内螺旋外棘齿管 强化传热 无铜化运行 Condenser Ammonia corrosion Spirally fluted tube Ratchet tube with internal spiral groove Heat transfer en-hancement No copper in heating system
  • 相关文献

参考文献7

二级参考文献24

  • 1周国定.交流阻抗法在电力设备腐蚀研究中的应用[J].中国电力,1994,27(10):24-29. 被引量:12
  • 2思勤,夏清,梁龙虎,李定绪.螺旋扁管换热器传热与阻力性能[J].化工学报,1995,46(5):601-608. 被引量:53
  • 3-.化学工程手册[M].化学工业出版社,1989(5).21-250,376,373.
  • 4窦照英.电力工业的腐蚀与防护[M].北京:化学工业出版社,1995..
  • 5西安热工研究所.热工技术手册(电厂化学)[M].北京:水利电力出版社,1993..
  • 6杨武 顾浚祥 等.金属的局部腐蚀[M].北京:化学工业出版社,1993..
  • 7龚洵洁.热力设备的腐蚀与防腐[M].北京:中国电力出版社,1998..
  • 8西安热工所情报室(译).-[J].热力发电,1973,(7):1-43.
  • 9沈祖灿(译).热能动力设备金属的腐蚀与防护[M].北京:水利电力出版社,1988..
  • 10沈祖灿(译).火力发电厂大容量机组水化学工况[M].北京:电力工业出版社,1982..