非刚体配准在肝癌手术中的应用 被引量:1

Application of nonrigid registration in liver cancer treatment
原文传递
导出
摘要 提出了一种在由MR图像引导的肝癌手术中对癌症肿块定位的方法。该方法采用非刚体配准技术,将手术前获得的含有清晰肝癌肿块的CT图像与手术中实时获得的MR图像配准,从而确定MR图像中的癌症肿块的位置。该方法分为三个步骤:将CT和MR图像中的肝脏部位分割出来;对分割后的图像采用仿射变换进行粗配准;采用自由形变模型对图像进行精确配准。配准后肝脏表面的距离误差在1.5mm之内;通过视觉检查,其结果令人十分满意。 A semiautomatic nonrigid registration is proposed to match preoperative CT images and real-time MR images during the ablation of liver tumors.The method includes three parts.Firstly,the livers are extracted from CT and MR images.Since the CT image is acquired a several days before surgery,there is enough time for surgeons to segment the liver from the CT image manually.During the surgery,active contour is used to extract the liver from the MR image.Then,affine registration to match the images roughly.Finally,high accuracy registration is reached by free-form deformation registration.The results are evaluated by visual inspection and the distance of two liver surfaces.The error of liver surfaces is within 1.5 mm and the result of visual inspection is very well.
出处 《光学技术》 CAS CSCD 北大核心 2006年第z1期369-370,373,共3页 Optical Technique
关键词 非刚体配准 MR和CT图像 肝癌手术 nonrigid registration MR and CT Image liver cancer treatment
  • 相关文献

参考文献8

  • 1[1]Curley S A.Radiofrequency ablation of malignant liver tumors[J].Annals of Surgical Oncology,2003,10:338-347.
  • 2[2]Morikawa S,lnubushi T,Kurumi Y,et al.MR-Guided microwave thermocoagulation therapy of liver tumors:initial clinical experiences using a 0.5 T open MR system[J].J Magn Reson Imaging,2002,16:576-583.
  • 3[3]Venot A,Golmard J L,Lebruchec J F,et al.Digital methods for change detection in medical imnges[J].Information processing in medical imaging,1983,16.
  • 4[4]Scott A M.,Macapinlac H,Zhang J,et al.Image registration of SPECT and CT images using an external fiduciary band and threedimensional surface fitting in metastatic thyroid cancer[J].Journal of nuclear medicine,1995,36:100~103.
  • 5[5]Mehrdad S,et al.Automatic CT SPECT registration of livers treated with radioactive microspheres[J].Phys Med Biol,2004,49.
  • 6[6]Andres C,Jeffrey L D,Jonathan S L,et al.Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatment[J].IEEE Transaction on Medical Imagmg,2000,19:175-185.
  • 7[7]Xu C,Prince J L.Snake,shape,and gradient vector flow[J].IEEE Trans On Image Processing,1998,7(3):359-369.
  • 8[8]Rueckert D,Sonoda L 1,Hayes C D,et al.Nonrigid registration using free-form deformations:application to breast MR images[J].IEEE Transaction on Medical lrnagmg,1999,18(8):712-721.

同被引文献1

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部