制冷型红外探测器组件降温时间的影响因素

Factors affecting cool-down time of cooled IR detectors
下载PDF
导出
摘要 以工作物质的一定压力、温度为基准状态,定义了组件热容量影响系数、工质状态(压力/温度)影响系数、流量影响系数等参数,为红外探测器组件的降温时间计算建立理论模型,用该模型计算分析了高温环境下组件的热容量和工质制冷量的变化对降温时间的影响,并和实验结果进行了比较。另外分析了实际情况小幅偏离基准状态对实验结果的影响。 The specific heat,cryogen state(pressure/temperature) and flow rate coefficient on cool-down time of IR detectors are defined based on specified cryogen state.A theoretic cool-down time model of IR detector assembly is established.With this model,the effects,that influenced by the specific heat of detector assembly and cryogen refrigeration power,to the cool-down time are calculated and analyzed.The calculation is compared with the experiment results.On the other hand,the effect of differential bias to the standard state is analyzed.
出处 《红外与激光工程》 EI CSCD 北大核心 2006年第z5期203-208,共6页 Infrared and Laser Engineering
关键词 制冷 降温时间 焓差 环境温度效应 Cooling Cool-down time Enthalpy difference Effect of environmental temperature
  • 相关文献

参考文献5

  • 1[2]TOULOUKIAN Y S,BUYCO E H.Thermophysical Properties of Matter Vol.5 Specific Heat nonmetallic solids[M].New York:Plenum Press,1970.
  • 2[3]TOULOUKIAN Y S,BUYCO E H.Thermophysical Properties of Matter Vol.4 Specific Heat Metallic Elements and Alloys[M].New York:Plenum Press,1970.
  • 3[4]STEWART R B,JACOBSEN R T.Thermodynamic properties of argon from the triple point to 1200k at pressures to 1000MPa[J].J.Phys.Chem.Ref.Data,1989,2:639-798.
  • 4[5]SPAN R,JACOBSEN R T.A reference equation of state for the thermodynamic properties of nitrogen for temperatures from 63.151 to 1000 K and pressures to 2200MPa[J].J.Phys.Chem.Ref.Data,2000,6:1361-1433.
  • 5[6]MAYTAL B Z.Realgas choked flow conditions at low reduced-temperatures[J].Cryogenics,2006,1:21-29.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部