介绍了方波电压法测量液体介质 tanδ的原理。分析了实现这一测量方法的技术关键。在测量系统的趋稳时间、测量时间的控制、测量系统各参数的设置和电流测量仪器选用等方面 ,提出了通过实践验证的计算方法和解决方案 ,并证实该方法是测量液体介质低 tanδ值 。
Principle of tanδ measurement in liquid dielectric is introduced using rectangular waveform voltage. Technical key to realization of the measurement is analyzed. With respect to time approaching a stable measured value in the measuring system, control in measuring time, set up various parameters in the system, and instrument selection for current measurement, calculation method and solutions are proposed based on successful experiences. And these methods are proved to be an effective way to measure low tanδ of liquid dielectric with better measurement resolution and accuracy.
出处
《电力电容器与无功补偿》
2001年第4期38-41,共4页
Power Capacitor & Reactive Power Compensation
关键词
方波电压
电导率
趋稳时间
损耗因数
液体介质
Rectangular voltage waveform
Conductivity
Time to approach a stabe measured value
Loss factor
Liquid dielectric