摘要 采用处理烟气量为200 Nm3/h的线-板式脉冲流光放电反应器进行了模拟烟气脱硫实验研究。在一定实 验条件下,研究了电压、脉冲成形电容及不同线-线间距与线-板间距的配置对反应器的脱硫效率及能量消耗的 影响.结果表明:随着电压、脉冲成形也容的增大,反应器脱硫效率升高,但反应器的能量消耗增大;在线-板 间距10 cm条件下,最佳线-线间距为6-10 cm时,反应器能量密度最大,脱硫效率最高,且能量消耗最低。在 最小能耗16.7 eV/mol下,脱硫效率达85%. The effects of voltage, pulse-forming capacitance and electrode configuration on the SO2 removal efficiency and energy cost have been investigated in a wire-plate pulsed streamer discharge reactor with flow rate of 200Nm3/h. Increasing voltage and pulse-forming capacitance can increase the removal efficiency of SO2, but also increase energy cost. Under the optimal conditions of 6-10cm wire-to-wire spacing and 10cm wire-to-plate spacing, the highest removal efficiency of increases and more than 85 % and the lowest energy cost of 16.7 eV/mol sind obtained.
作者 董冰岩 吴彦
出处 《北京理工大学学报》 EI CAS CSCD 北大核心 2005年第z1期208-211,共4页 Transactions of Beijing Institute of Technology
基金 国家"八六三"计划项目(2001AA642010)
关键词 脉冲流光放电 脱硫效率 能量消耗 电极配置 pulsed streamer discharge SO2 removal efficiency energy cost electrode configuration
  • 相关文献

参考文献7

  • 1[1]Dinelli G, Civitano L, Rea M. Industial experiments on pulse simultaneous removal of NOx and SOx from flue gas [J]. IEEE Trans Ind Appl, 1990, 26(3): 535-541.
  • 2[2]Wu Y, Zhu Y, Wang N. SO2 removal from industrial flue gases using pulsed corona discharge [J]. J Electrostatics,1998, 44: 11-16.
  • 3[3]Wu Yan, Li Jie, Wang Ninghui. Industrial experiments on desulfurization of flue gases by pulsed corona induced plasma chemical process [J]. J Electrostatics, 2003, 57:233-241.
  • 4[4]Lee Y H, Jung W S, Choi Y R. Application of pulsed corona induced plasma chemical process to an industrial incinerator [J]. Environ Sci Technol, 2003, 37(11): 2563-2567.
  • 5[5]Dong Bingyan, Li Jie ,Wu Yan, et al. Experimental study of secondary streamer energy in pulsed corona discharge [J].Jpn J Appl Phys, 2005, 4A: 1959-1960.
  • 6[6]Kima H H, Mizuno G P. Performance evaluation of discharge plasma process for gaseous pollutant removal [J].J Electrostatics, 2002, 55: 25-41.
  • 7[7]Mok Y S. Efficient energy delivery condition from pulse generation circuit to corona discharge reactor [J]. Plasma Chemistry and Plasma Processing, 2000, 20:353-364.