摘要 基于集成气敏传感器阵列和多传感器信息融合技术的电子鼻系统 ,可用于气体 /气味的定性定量识别 .在实际应用中 ,被识别样本的浓度、样本环境的温度和湿度参数等都对电子鼻系统的响应特性有较大的影响 .本文分别利用纯净空气及乙醇或葡萄酒作为载气及分析样本 ,对电子鼻系统响应特性与气敏传感器工作温度以及样本温度、环境湿度、样本浓度间的依赖关系进行了实验分析 ,并分别给出了它们间依赖关系的实验结果 . Electronic nose system based on integrated gas sensitive sensors array and multi sensors information fuse technology can be used to identify qualitative and quantitative gas/odor. In actual applications, the factors of sample concentration, sample temperature and humidity of circumstance will have strict effects on the response characteristic of the electronic nose system. In this paper, we study the relations of the system response characteristic changing with the sensors work temperature and sample temperature, humidity and concentration of sample using the home made experimental system. In the experiments, pure and dry air has been used as carrier air and ethanol in different concentration, while wine and water have been used as sample.
出处 《传感技术学报》 CAS CSCD 2002年第3期197-202,共6页 Chinese Journal of Sensors and Actuators
基金 国家自然基金资助 (批准号 :6990 2 0 0 6)
关键词 集成气敏传感器阵列 电子鼻 响应特性 integrate gas sensitive sensors array electronic nose response characteristic
  • 相关文献

参考文献2

二级参考文献7

  • 1梁坚,辛德瑗,陆毅新,沈悦,胡真.电子鼻——智能气体传感器[J].传感技术学报,1995,8(2):11-14. 被引量:9
  • 2徐毓龙.国外气敏传感器的发展动向[J].传感器世界,1996,2(1):21-28. 被引量:10
  • 3冯伟.溴觉传感器技术和模式识别分类技术:博士学位论文[M].浙江大学,1994,6..
  • 4杨燕明.基于阵列声表面波传感器的电子鼻系统及应用研究:博士学位论文[M].厦门:厦门大学,1996..
  • 5杨燕明,博士学位论文,1996年,12页
  • 6冯伟,博士学位论文,1994年
  • 7康昌鹤,气、湿敏感器元件及其应用,1988年

共引文献28

同被引文献129

引证文献18

二级引证文献100

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部