摘要
本文对一台绝缘油色谱异常的集合式电容器进行了分析,找出原因,提出解决方法,通过实践证明集合式电 容器运行中应增加绝缘油色谱试验项目。
In this paper analyzed the chromatogram - abnormity of the insulation oil in one set of aggregative - type capacitor, the author found out the reason, and presented a solving way. The practice proved that the insulation oil chromatogram test should be carried out in the operation of aggregative - type capacitor.