期刊文献+

铜接地体技术在GIS变电站工程中的探索与实践

Research and Practice of Copper-made Grounding Device Technique in GIS Substation Project
下载PDF
导出
摘要 本文通过阐述铜接地体技术的基本原理,结合广东省江门市220kV新会变电站和广东省台山电厂220kV铜鼓升压站等GIS配电装置变电站工程实例,分析铜接地体与常规接地体的优劣与互补性,探索出一套适用于GIS变电站的铜接地体技术。 In this paper, introducing the principle of copper-made crounding device, the author combines the GIS project instances, such as 220kV Xinhui Substation in Jiangmen City Guangdong Province, and 220kV Tonggu Taishan Plant' s Tonggu Setup Station, analyses the advantage /defect and complementarity of Copper-made Grounding Device and generic Grounding Device, and has researched a technology of Copper-made Grounding Device that is suitable for the GIS Substation.
出处 《广东输电与变电技术》 2004年第5期41-46,共6页 Guangdong Power Transmission Technology
关键词 SF6气体绝缘全封闭组合电器(GIS) 铜接地体 触摸电压 接地线连接头 GIS Copper-made Grounding Device Touch Voltage Connection joint for grounding lead
  • 相关文献

参考文献5

二级参考文献4

  • 1IEEE Std80-2000. IEEE Guide for safety in AC substation Grounding. Jan. 2000.
  • 2IEEE Std837-1989. IEEE standard for Qualifying permanent connections Used in Substation Grounding. Jan. 1989.
  • 3.DL/11621—1997.交流电气装置的接地[M].北京:中国电力出版社,1997年..
  • 4.DL/T5091-1999水力发电厂接地设计技术导则[M].北京:中国电力出版社,1999年..

共引文献14