期刊文献+

基于双探测器校正的分段γ扫描技术研究 被引量:7

An improved gamma scanning technique using two detectors at off-center positions
下载PDF
导出
摘要 将探测器对准废物桶两个不同偏心位置进行测量,由两个位置计数率比值,确定桶内放射源所在等效半径位置,从而计算其活度。对非均匀样品进行了测量,结果显示,测量结果误差在10%以内。 The equivalent radius of source in a waste drum was determined based on counting rate ratio of two detectors located at off-center positions.The experimental data of a non-uniform sample was presented and compared to that of conventional SGS.The results confirm that the analysis errors are reduced greatly by the technique proposed.
出处 《核技术》 CAS CSCD 北大核心 2010年第5期342-345,共4页 Nuclear Techniques
基金 国家自然科学基金(10675084)资助
关键词 分段γ扫描 探测效率 等效半径 Segmented gamma scanning Detection efficiency Equivalent radius
  • 相关文献

参考文献1

共引文献19

同被引文献34

  • 1朱荣保,谭亚军,袁晓鑫,吕钊,曹斌,吴昕,程炳皓,许晓东,江金才.大型高分辨分段γ扫描装置的研制[J].原子能科学技术,1994,28(1):16-25. 被引量:13
  • 2何丽霞,吕峰,赵学军,隋洪志,刘亨军,李泽.分段γ扫描标样的非破坏性分析法检验[J].原子能科学技术,2007,41(2):248-251. 被引量:3
  • 3祁昌明.秦山第二核电厂放射性废物管理进展[J].辐射防护通讯,2007,27(1):13-17. 被引量:5
  • 4张勇,沈吉,郑国文,等.秦山核电厂低中放固体废物管理及现状分析[c]//低中放废物管理和放射性物质运输学术研讨会.北京:中国核学会,2005:66-72.
  • 5STANGA D, RADU D, SIMA O. A new model calculation of the peak efficiency for HPGe detec- tors used in assays of radioactive waste drums [J]. Applied Radiation and Isotopes, 2010, 68 (7): 1 418-1 422.
  • 6NAN Q, THOMAS K, MAUERHOFER E, et al. Analytical calculation of the collimated detec- tor response for the characterization of nuclear waste drums by segmented gamma scanning[J]. Journal of Radioanalytical and Nuclear Chemis- try, 2012, 292(3): 1 325-1 328.
  • 7American Society for Test and Material. ASTM 1133-03, Standard test method for nondestructive assay of special nuclear material in low-density scrap and waste by segmented passive gamma-ray scanning[S]. USA: ASTM, 2003.
  • 8Reilly T D, Parker J L. A guide to gamma-ray assay for nuclear materials accountability[R]. LA-5794-M, USA: Los Alamos Scientific Laboratory, 1975.
  • 9Parker J L. The use of calibration standards and the correction for sample self attenuation in gamma-ray nondestructive assay[R]. LA-10045, USA: Los Alamos National Laboratory, 1986.
  • 10Bruggeman M, Gerits J, Carchon R. A minimum biased shell-source method for the calibration of rad waste assay systems[J]. Applied Radiation and Isotopes, 1999, 51(2): 255-259.

引证文献7

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部