期刊文献+

自动顶空GC/MS测定血液中乙醇含量不确定度评定 被引量:8

Evaluation of measurement uncertainty for the determination of ethanol in human blood by auto-headspace GC/MS
下载PDF
导出
摘要 目的评定自动顶空—气相色谱—质谱法(GC/MS)测定血液中乙醇含量的不确定度。方法从分析测量过程着手,依据不确定度评定的指导性文件,分析了不确定度来源,量化不确定度分量,计算检测结果的合成标准不确定度和扩展不确定度。结果血液样本两次测定结果平均值为0.738mg/mL的扩展不确定度为0.084mg/mL。结论血液中乙醇含量的不确定度主要来源于样品检测、乙醇标准溶液和标准曲线。 Objective To evaluate the measurement uncertainty for the determination of ethanol in human blood by auto-headspace GC/MS.Methods Each source of uncertainty,arising from the procedure of testing,was analyzed and confirmed according to the guidelines of the uncertainty in measurement.After each uncertainty component was evaluated,the combined standard uncertainty and the expanded uncertainty of the result were calculated.Results The expanded uncertainty was 0.084mg/mL when the concentration of ethanol in blo...
出处 《中国法医学杂志》 CSCD 北大核心 2010年第1期43-45,47,共4页 Chinese Journal of Forensic Medicine
关键词 法医毒物分析 测量不确定度 自动顶空GC/MS 乙醇 forensic toxicological analysis measurement uncertainty auto-headspace GC/MS ethanol
  • 相关文献

参考文献1

  • 1JJF 1059-1999.测量不确定度评定与表示[S],1999.

同被引文献110

引证文献8

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部