摘要 在屏蔽材料的屏蔽效能(shielding effectiveness,SE)测试装置中,通过对锥形连接器内导体进行微小移位,优化固定同轴装置的支撑介质的内、外径比值,并在支撑介质中挖去一定厚度的环形沟道构成小电感等技术对阶梯电容进行补偿,减小由截面不连续引起的回波损耗,设计了频率范围为10 MHz至3 GHz的SE同轴测试装置.利用软件仿真验证了表面电阻为5Ω的屏蔽材料在该装置中测试有稳定的SE值,证明该装置不仅改善了基于ASTM D4935测试装置频率范围窄的不足,同时具备良好的阻抗匹配特性. Tapering transitions were commonly used to connect coaxial fixtures and N-type coaxial interfaces in SE(shielding effectiveness) coaxial testers.Now,it has been optimized by shifting the inner conductors moderately,setting the ratio of inner and outer diameters of the brace mediums,and digging small rings in the brace mediums contact with the air to compensate the step capacitances.An SE coaxial tester with a wider frequency range from 10 MHz to 3 GHz was developed and its stable characteristics were valida...
出处 《中国计量学院学报》 2010年第2期99-103,共5页 Journal of China Jiliang University
基金 上海市科委资助项目(No.08DZ0501800) 浙江省自然基金杰出青年团队项目(No.R105248) 国家标准化公益专项项目(No.200810461) 国家自然科学基金资助项目(No.10802082) 浙江省自然科学基金资助项目(No.Y6090008)
关键词 屏蔽效能 阶梯电容 回波损耗 锥形过渡器 支撑介质 shielding effectiveness step capacitance return loss tapering connector brace medium
  • 相关文献

参考文献1

二级参考文献21

  • 1王素英.平板型复合屏蔽材料屏蔽效能测试技术的研究[J].安全与电磁兼容,1995(2):18-20. 被引量:9
  • 2李刚,蒋全兴,孔斌.平板型电磁屏蔽材料的同轴测试方法[J].电讯技术,1995,35(3):6-12. 被引量:18
  • 3熊汉.不锈钢纤维在纺织品的应用.纺织速报,:28-32.
  • 4.GJB2713-96.附录A[S].,..
  • 5.SJ20524-1995.材料的屏蔽效能测试方法[S].,..
  • 6.IEEE 299-1999[S].[S].,..
  • 7林芳辉.电磁屏蔽织物的开发[J].纤维加工,2001,51:17-20.
  • 8何中琴译.电磁波屏蔽方面的优良效果[J].印染译丛,1998,(7):77-80.
  • 9赵清译.电子设备的屏蔽设计[M].国防工业出版社,1975..
  • 10Protection from electromagnetic radiation[ J ]. High performance Textile, 1992,(7).

共引文献36

同被引文献33

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部