摘要
通过具体的设计项目,介绍了离心压缩机房的平面布置、配管布置和需要注意的问题,以及如何使用CAESARⅡ计算离心压缩机管嘴受力。通过合理的设备平面布置、选择适当管道支吊架形式、位置和合理管道布置,满足设备的受力要求,满足设备的正常运行及检、维修要求。
This paper takes Fujia project as an example to introduce the equipment layout and piping layout of centrifugal compressor house and the points for attention as well as how to calculate the force on pipe nozzle of centrifugal compressor based on CAESARII. The requirements on force on the pipe nozzle and the requirements on normal operation and maintenance of equipment can be met by means of reasonable equipment layout, proper selection of the type and location of pipe support as well as reasonable piping la...
出处
《石油化工设计》
CAS
2009年第3期48-50,21,共4页
Petrochemical Design
关键词
设备
压缩机
汽轮机
支架
Equipment
Compressor
Turbine
Support