期刊文献+

合成气生产中工艺冷凝液高电导率的原因分析及处理 被引量:1

Analysis And Solution For High Conductive Condensate In Steam Reforming Process
下载PDF
导出
摘要 天然气蒸汽转化制合成气生产工艺中的工艺冷凝夜,由于氨、二氧化碳和无机盐等的影响,使其电导率高达400~500μs/cm,而无法回收利用。生产中采用离子树脂除盐技术对工艺冷凝液进行处理,使其电导率不超过1μs/cm,达到了可回收利用的水质要求,并为企业带来了明显的经济效益和社会效益。 Due to presence of ammonia, CO_2 and inorganic salts, the conductivity of process condensate produced in the steam reforming of natural gas to syngas was as high as 400-500μs/cm, which makes it impossible to be reused. A technique of removing salts by ion exchange resin was adopted to treat the condensate, and it was able to make the conductivity not higher than 1μs/cm, which is acceptable for recovery and can bring remarkable economic and social benefit to the enterprise.
作者 管琦 潘永亮
出处 《天然气化工—C1化学与化工》 CAS CSCD 北大核心 2004年第3期27-30,共4页 Natural Gas Chemical Industry
关键词 蒸汽转化 工艺冷凝液 电导率 回收 steam reforming process condensate electrical conductivity
  • 相关文献

参考文献4

  • 1四川泸州天然气化工厂.天然气脱硫加压蒸气转化的工艺与操作[M].北京:石油化工出版社,1995..
  • 2陈浩.锅炉水处理技术问答[M].化学工业出版社,2003..
  • 3唐受印 戴友芝 张森林.水处理工程师手册[M].北京:化学工业出版社,2001.104-105.
  • 4顾夏声.水处理工程[M].北京:清华大学出版社,2000..