分析了高水头弧形工作闸门止水埋件安装工艺对水封安装质量的影响和闸门运行后止水橡皮发生局部磨损及渗漏的原因 ,并在此基础上提出埋件利于紧密止水的安装新工艺及在大型水利水电工程中的应用实例。
Based on the study of the installing workmanship of high-head radial gate which influenced the operating quality of sealing device and caused abrasion of rubber seal, an improved installing workmanship for it is recommended.
出处
《湖北水力发电》
2003年第2期30-32,共3页
Hubei Water Power
关键词
深孔弧门
水封渗漏
原因分析
埋件安装新工艺
radial gate of deep outlet, leakage through seal device, cause analysing, new workmanship for installing embedded metal parts