Determination of Trace Thiocyanate by a Chitosan-Modified Glassy Carbon Electrode 被引量:2

Determination of Trace Thiocyanate by a Chitosan-Modified Glassy Carbon Electrode
下载PDF
导出
摘要 A chitosan modified glassy carbon electrode(CMGCE) was employed for the determination of thiocyanate. The measurement was carried out by means of anodic stripping voltammetry. The effects of several experimental parameters, such as pH, the amount of modifier, deposition potential and deposition time were studied for analytical application, respectively. A liner response was obtained in the concentration range of 3 5×10 -8 - 9.3×10 -7 g/mL of SCN -. The detection limit was found to be 1.9×10 -8 g/mL. The method was satisfactorily used to detect SCN - in saliva. A chitosan modified glassy carbon electrode(CMGCE) was employed for the determination of thiocyanate. The measurement was carried out by means of anodic stripping voltammetry. The effects of several experimental parameters, such as pH, the amount of modifier, deposition potential and deposition time were studied for analytical application, respectively. A liner response was obtained in the concentration range of 3 5×10 -8 - 9.3×10 -7 g/mL of SCN -. The detection limit was found to be 1.9×10 -8 g/mL. The method was satisfactorily used to detect SCN - in saliva.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2002年第3期316-320,共5页 高等学校化学研究(英文版)
基金 Supported by the Nature Science Fund Project of Hubei Province
关键词 Anodic stripping voltammetry THIOCYANATE CMGCE SALIVA Anodic stripping voltammetry Thiocyanate CMGCE Saliva
  • 相关文献

参考文献1

二级参考文献4

共引文献2

同被引文献43

  • 1李发生,王素芳.玻碳金膜电极线性扫描微分阳极溶出伏安法分析测定水样中痕量硒(Ⅳ)及硒(Ⅵ)[J].中国环境监测,1994,10(2):44-48. 被引量:2
  • 2张晓丽,王丽增,马成松,张青.痕量硒的吸附伏安法测定[J].山东大学学报(自然科学版),1995,30(2):186-189. 被引量:2
  • 3臧树良,王歆睿,铁梅,孙铁彪,田冬梅,邓桂春.阴极溶出伏安法测定痕量硒(Ⅳ)[J].辽宁大学学报(自然科学版),2005,32(4):289-292. 被引量:5
  • 4Achterberg E P, Barriacla J L, Braungardt C B. Cathodic stripping voltammetry[J]. Encycloped of analytical science, 2005 (2) .. 203-211.
  • 5Danielc S. Anodic stripping voltammetry [ J ]. Encycloped of analytical science, 2005 ( 2 ) .. 197-202.
  • 6EUeouei C, Queniet F, Madec C. Determination of inorganic and organic selenium species in natural by cathodic stripping voltammetry[J], water Research, 1996,30(4) :909-914.
  • 7Ochsenkuhn-Perropoulou M, Tsopelas F. Speciation analysis of selenium suing voltammetric techniques[J]. Anal Chim Acta,2002,467(1/2):167-178.
  • 8Recai I,Guler S. Determination of selenium in garlic by cathodic stripping voltammetry [ J ]. Food Chemistry, 1999,66 .. 381-385.
  • 9Recai I, Guler S. A direct method for the determination of selenium and lead in cow's milk by dif{erential pulse stripping voltammetry [J]. Food Chemistry, 2000 : 345-350.
  • 10Anca-Iulia S, Gobriela-Raluca B, Emilia-Elena L, et al. Differential pulse caihodic stripping voltammetrie determination of selenium in pharrnacentical products[J]. Journal of Phormacentical and Biomedical of Analysis,2002,30(4),1425-1429.