期刊文献+

形状记忆合金环抱器在骨折中的应用(英文) 被引量:1

THE APPLICATION OF SHAPE MEMORY ALLOY ENCIRCLED FIXER TO BONE FRACTURE
下载PDF
导出
摘要 Objective:To evaluate the effect of encircled fixer of shape memory alloy on bone fracture. Methods:A total of twenty patients with eighteen males and two females was studied. There were three patients with fractares in the upper one third of thighbone, five with fractures in the middle part of thighbone, six with humeral fractures, three with collarbone fractures,one with ulna fracture and two with thighbone fractures as complication of artificial hipbone arthroplasty. After exposure and fixation of fracture ends, prepared encircled fixer was inserted into 0~4℃ normal reline(NS) to lower its temperature, then pulled out with a clamp. Encircled fixer was put on the tersile side of the fractured bone(center pointed to fracture line), restored and stabilized after raising temperature in 40℃ NS. Results: Encircled fixers of shape memory alloy were used to treat twenty patients with bone fracture.Clinical concrescence was obtained in 1.5 to 3 months after operation,and the joint gained its normal function without complication. Conclusion:Encircled fixer of shape memory alloy has features as exerting vertical pressure continoulsy, little stress shield effect and convenient manipulation, especially adapt to stem fracture after artificial arthroplasty. Objective:To evaluate the effect of encircled fixer of shape memory alloy on bone fracture. Methods: A total of twenty patients with eighteen males and two females was studied. There were three patients with fractares in the upper one third of thighbone, five with fractures in the middle part of thighbone, six with humeral fractures, three with collarbone fractures,one with ulna fracture and two with thighbone fractures as complication of artificial hipbone arthroplasty. After exposure and fixation of fracture ends, prepared encircled fixer was inserted into 0-4℃ normal saline(NS) to lower its temperature, then pulled out with a clamp. Encircled fixer was put on the tensile side of the fractured bone(center pointed to fracture line) .restored and stabilized after raising temperature in 40℃ NS. Results: Encircled fixers of shape memory alloy were used to treat twenty patients with bone fracture. Clinical concrescence was obtained in 1.5 to 3 months after operation, and the joint gained its normal function without complication. Conclusion:Encircled fixer of shape memory alloy has features as exerting vertical pressure conti-noulsy,little stress shield effect and convenient manipulation, especially adapt to stem fracture after artificial arthroplasty.
出处 《中国医学工程》 2002年第6期24-25,共2页 China Medical Engineering
关键词 Shape Memory Alloy Encircled Fixer FIXATION Bone Fracture Shape Memory Alloy, Encircled Fixer, Fixation, Bone Fracture
  • 相关文献

参考文献2

二级参考文献1

  • 1杨佩君,中华创伤杂志,1991年,7卷,69页

共引文献201

同被引文献4

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部