期刊文献+

An Analysis on the Diagnostic Values of Transcranial Doppler and Angiography in Transient Ischemic Attack 被引量:6

An Analysis on the Diagnostic Values of Transcranial Doppler and Angiography in Transient Ischemic Attack
下载PDF
导出
摘要 The accuracy and diagnostic values of transcranial Doppler (TCD) in transient ischemic attack (TIA) caused by the stenosis or occlusion of intracranial or extracranial blood vessels were investigated. Of the 50 TIA patients receiving routine TCD examinations, 39 cases (77 %) were diagnosed as having unilateral or bilateral stenosis or occlusion of MCA, ACA, siphon segment of internal carotid artery, which was furthermore confirmed by digital subtraction angiography (DSA) or MRA, 11 (22 %) cases were normal. An analysis on the TCD findings of the flow patterns and hemodynamic changes of the stenotic or occluded blood vessels was made in comparison with that obtained by angiography. It was showed that angiography demonstrated 17 unilateral MCA stenosis, 47 bilateral multi stenosis, 1 occlusion of the siphon segment of the internal carotid artery, while TCD revealed 17 unilateral stenosis, 64 bilateral stenosis, 1 occlusion respectively, with an accordance rate of 78.7 %. It was concluded that the hemodynamic changes secondary to the stenosis of the basalcranial arteries, especially the moderate to severe stenosis or occlusion, might be an important risk factor for TIA. TCD examination achieved significant clinic values in the diagnosing of TIA. The accuracy and diagnostic values of transcranial Doppler (TCD) in transient ischemic attack (TIA) caused by the stenosis or occlusion of intracranial or extracranial blood vessels were investigated. Of the 50 TIA patients receiving routine TCD examinations, 39 cases (77 %) were diagnosed as having unilateral or bilateral stenosis or occlusion of MCA, ACA, siphon segment of internal carotid artery, which was furthermore confirmed by digital subtraction angiography (DSA) or MRA, 11 (22 %) cases were normal. An analysis on the TCD findings of the flow patterns and hemodynamic changes of the stenotic or occluded blood vessels was made in comparison with that obtained by angiography. It was showed that angiography demonstrated 17 unilateral MCA stenosis, 47 bilateral multi stenosis, 1 occlusion of the siphon segment of the internal carotid artery, while TCD revealed 17 unilateral stenosis, 64 bilateral stenosis, 1 occlusion respectively, with an accordance rate of 78.7 %. It was concluded that the hemodynamic changes secondary to the stenosis of the basalcranial arteries, especially the moderate to severe stenosis or occlusion, might be an important risk factor for TIA. TCD examination achieved significant clinic values in the diagnosing of TIA.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第2期100-101,共2页 华中科技大学学报(医学英德文版)
关键词 TIA arterial stenosis HEMODYNAMIC TCD TIA arterial stenosis hemodynamic TCD
  • 相关文献

参考文献3

二级参考文献2

共引文献54

同被引文献19

引证文献6

二级引证文献109

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部