摘要
The influence of pulsed magnetic stimulation on the sciatic nerve injury was investigated. Thirty rats were divided into three groups equally: MS group , electric stimulation group and the control group . The MS and ES were applied immediately after the first 10 min of the sciatic nerve crush. Sciatic function index , toe spreading reflex , muscular weight and volume were measured after the experiment. The TSR of in the groups A and B occurred at 4th day while in the control group it occurs at 10th day. There was statistically significant difference in SFI between groups A and B . The weight and volume of the gastrocnemius muscle were statistically greater in the groups A and B than in the control group . The effect of MS was similar to that of ES. It was suggested that the application of MS immediately after the nerve injury might have an important clinical value as it can accelerate functional recovery and prevent or minimize muscle atrophy. The technique is easily to operate, non invasion, painless and permits tolerance of high intensity output to be used.
The influence of pulsed magnetic stimulation on the sciatic nerve injury was investigated. Thirty rats were divided into three groups equally: MS group , electric stimulation group and the control group . The MS and ES were applied immediately after the first 10 min of the sciatic nerve crush. Sciatic function index , toe spreading reflex , muscular weight and volume were measured after the experiment. The TSR of in the groups A and B occurred at 4th day while in the control group it occurs at 10th day. There was statistically significant difference in SFI between groups A and B . The weight and volume of the gastrocnemius muscle were statistically greater in the groups A and B than in the control group . The effect of MS was similar to that of ES. It was suggested that the application of MS immediately after the nerve injury might have an important clinical value as it can accelerate functional recovery and prevent or minimize muscle atrophy. The technique is easily to operate, non invasion, painless and permits tolerance of high intensity output to be used.