期刊文献+

PREPARATION AND PROPERTIES OF HIGH STRENGTH RODS FROM L-AND D,L-LACTIDE COPOLYMER 被引量:2

PREPARATION AND PROPERTIES OF HIGH STRENGTH RODS FROM L-AND D,L-LACTIDE COPOLYMER
下载PDF
导出
摘要 Starling with the L- and D,L-lactide copolymer (L:DL = 9:1) [P(L-DL)LA] of M-W = 32.1 x 10(4), rods were obtained through a two stage process: (1) melt-extrusion at 155 degreesC, and (2) hot-drawing at 90 degreesC to various drawing ratios. The molecular weight of P(L-DL)LA fell to 9.3 x 10(4) as a consequence of the production process. The crystallization and molecular orientation of P(L-DL)LA developed as a result of the hot-drawing. The mechanical strengths of the rods increase with the drawing ratio; The maximum for tensile strength, bending strength, bending modulus, and shear strength are 329 MPa, 237 MPa, 8.8 GPa, and 157 MPa, respectively. Starling with the L- and D,L-lactide copolymer (L:DL = 9:1) [P(L-DL)LA] of M-W = 32.1 x 10(4), rods were obtained through a two stage process: (1) melt-extrusion at 155 degreesC, and (2) hot-drawing at 90 degreesC to various drawing ratios. The molecular weight of P(L-DL)LA fell to 9.3 x 10(4) as a consequence of the production process. The crystallization and molecular orientation of P(L-DL)LA developed as a result of the hot-drawing. The mechanical strengths of the rods increase with the drawing ratio; The maximum for tensile strength, bending strength, bending modulus, and shear strength are 329 MPa, 237 MPa, 8.8 GPa, and 157 MPa, respectively.
出处 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2001年第4期351-357,共7页 高分子科学(英文版)
关键词 P(L-DL)LA self-reinforcement ROD process bone fracture fixation P(L-DL)LA self-reinforcement rod process bone fracture fixation
  • 相关文献

同被引文献24

  • 1崔红星,张倩.聚乳酸类可吸收手术缝合线的研究进展[J].合成纤维,2004,33(4):15-16. 被引量:20
  • 2田怡,钱欣.聚乳酸的结构、性能与展望[J].石化技术与应用,2006,24(3):233-237. 被引量:40
  • 3刘夏君,彭程,肖涛.生物可降解材料构建组织工程软骨的研究进展[J].中国生物工程杂志,2006,26(12):99-106. 被引量:6
  • 4周晓军,金玉顺,郭文莉,李树新.L-丙交酯的制备与聚合研究[J].塑料工业,2007,35(B06):115-117. 被引量:3
  • 5Konan S, Haddad FS.A clinical review of bioabsorbable interfer- ence screws and their adverse effects in anterior cruciate ligament re- construction sugery[J].Knee, 2009,16( 1 ) : 6-13.
  • 6Sudkamp NP,Kaab MJ.Biodegradable implants in soft tissue refix- ation experimental evaluationclinical experience and future needs[J].In- jury, 2002,33 (s2) : B 17-B24.
  • 7Walton M.Absorbable and metal interference screws:comparison of graf security during healing[J].Arthroscopy, 1999,15 (8) : 818-826.
  • 8Narin F,Noma E.Is technology becoming science[J].Scientometrics, 1985,7(3) :369-381.
  • 9Pcrsson O.The intellectual base and research fronts of jasis 1986- 1990[J].Journal of the American Society for Information Science, 1994, 45(1) :31-38.
  • 10BSstman O, Hirvensalo E, Makinen J, et al .Foreign-body reactions to fracture fixation implants of biodegradable synthetic-polymers [J].J Bone Joint Surg Br, 1990(72) : 572-576.

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部