期刊文献+

Temporary self-expanding metallic stents for achalasia: A prospective study with a long-term follow-up 被引量:9

Temporary self-expanding metallic stents for achalasia: A prospective study with a long-term follow-up
下载PDF
导出
摘要 AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively.RESULTS: Stent placement was successful in all patients. Although chest pain occurrence was high, stent migration was less in group C than in groups A and B. The clinical remission rate at 5-8, 8-10 and > 10 years in group C was higher than that in the other two groups. The treatment failure rate was lower in group C (13%) than in groups A (53%) and B (27%). SEMSs in group C resulted in reduced dysphagia scores and lowered esophageal sphincter pressures, as well as normal levels of barium height and width during all the follow-up time periods. Conversely, these parameters increased over time in groups A and B. The primary patency in group C was longer than in groups A and B. CONCLUSION: A temporary SEMS with a diameter of 30 mm is associated with a superior long-term clinical efficacy in the treatment of achalasia compared with a SEMS with a diameter of 20 mm or 25 mm. AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively.RESULTS: Stent placement was successful in all patients. Although chest pain occurrence was high, stent migration was less in group C than in groups A and B. The clinical remission rate at 5-8, 8-10 and > 10 years in group C was higher than that in the other two groups. The treatment failure rate was lower in group C (13%) than in groups A (53%) and B (27%). SEMSs in group C resulted in reduced dysphagia scores and lowered esophageal sphincter pressures, as well as normal levels of barium height and width during all the follow-up time periods. Conversely, these parameters increased over time in groups A and B. The primary patency in group C was longer than in groups A and B. CONCLUSION: A temporary SEMS with a diameter of 30 mm is associated with a superior long-term clinical efficacy in the treatment of achalasia compared with a SEMS with a diameter of 20 mm or 25 mm.
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第40期5111-5117,共7页 世界胃肠病学杂志(英文版)
基金 Supported by The National 9th Five-Year Plan Key Medical Research and Development Program of China, No. 96-907-03-04 Shanghai Natural Science Funds, No. 02Z1314073 Shanghai Medical Development Funds, No. 00419 the National Natural Science Foundation of China, No. 30670614 and 30970817
关键词 ACHALASIA DYSPHAGIA Self-expanding metallic stents COMPARISON Achalasia Dysphagia Self-expanding metallic stents Comparison
  • 相关文献

同被引文献72

引证文献9

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部