摘要 目的:探讨心电图编辑在提高64排螺旋CT冠状动脉成像质量中的作用。方法:收集38例检查前已知心律失常或在检查过程中出现不可预知的心律失常或心电信号异常消失患者的冠脉成像质量进行分析评价,并与进行心电图编辑后图像质量进行对照。结果:38例中检查前发现心律失常6例,4例房性早搏,2例偶发性室性早搏,在扫描过程中突然出现窦性心动过速6例,室性早搏5例,房性早搏18例,房顫2例,1例为扫描过程中突然出现心电信号脱失。心电编辑前可评价冠脉节段占84.01%,心电编辑后可评价冠脉节段占93.08%,对心电图编辑前后可评价、不可评价冠脉节段运用2检验,得出P<0.05。结论:心电图编辑软件的应用,可以明显提高图像质量,增加检查成功率,扩大无创冠状动脉造影检查的临床应用范围。 Objective:To explore the role of ECG editing to improve 64-slice spiral CT coronary angiography.Methods:38 patients with known arrhythmia or investigation before appearing in the examination process unpredictable disappearance of arrhythmia or ECG abnormalities in patients with coronary artery imaging quality analysis and evaluation,and editing images with electrocardiogram quality control.Results:38 cases of arrhythmia before the test was found in 6 cases,4 cases of atrial premature beats,two cases of sporadic premature ventricular contractions,and the other 32 cases were scanned during the sudden appearance of sinus tachycardia in 6 cases,5 cases of premature ventricular contractions,18 cases of atrial premature beats,atrial fibrillation in 2 cases,1 patient during the scan ECG suddenly dropped out.ECG pre-editing of coronary segments can be accounted for 84.01%,after ECG editing of coronary segments accounted for 93.08%.Before and after ECG editing can be on the evaluation of coronary segments can not evaluate the use of χ2 test,reached P<0.05.Conclusion:ECG-editing software applications,can significantly improve image quality and increase check the success rate of expansion of non-invasive coronary angiography for clinical aplications.
出处 《医学影像学杂志》 2011年第5期671-674,共4页 Journal of Medical Imaging
关键词 心律失常 冠状动脉成像 体层摄影术 X线计算机 心电图编辑 Coronary artery imaging Tomography,X-ray computed ECG editing Arrhythmia
  • 相关文献

参考文献8

  • 1赵红,刘斌,吴兴旺,余永强,沈云,廖静敏.64层螺旋CT冠状动脉成像的心率变化及其对图像质量的影响[J].实用放射学杂志,2007,23(2):145-149. 被引量:48
  • 2张敏,李石玲,郭智萍,张英华,王凤珍.64层螺旋CT冠状动脉血管成像技术[J].中国医学影像技术,2005,21(12):1948-1950. 被引量:24
  • 3王锡明,武乐斌,李振家,柳澄,陈海松.64层螺旋CT在冠状动脉造影中的应用[J].中华放射学杂志,2005,39(11):1201-1204. 被引量:150
  • 4Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation . 1975
  • 5Hong C,Becker CR,Huber A,et al.ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology . 2001
  • 6Giesler T,Baum U,Ropers D,et al.Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. American Journal of Roentgenology . 2002
  • 7Schroeder S,Kopp AF,Kuettner A,et al.Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clinical Imaging . 2002
  • 8Hyun Seok Choi,Byoung Wook Choi,Kyu Ok Choe,et al.Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography. Radiographics . 2004

二级参考文献19

  • 1姜荣,吴晓华,贺文.心率波动对多层螺旋CT冠脉造影图像质量的影响[J].中国医学影像技术,2004,20(10):1574-1576. 被引量:49
  • 2邵广瑞,柳澄,刘延军,王道萍.多层螺旋CT与选择性冠状动脉造影对照研究及其临床应用[J].中华放射学杂志,2003,37(9):805-808. 被引量:80
  • 3杨明放,王荣品,何强.16层CT冠状动脉成像技术及临床应用[J].实用放射学杂志,2005,21(9):915-918. 被引量:21
  • 4张敏,李石玲,郭智萍,张英华,王凤珍.64层螺旋CT冠状动脉血管成像技术[J].中国医学影像技术,2005,21(12):1948-1950. 被引量:24
  • 5Ritchie CJ, Godwin JD, Crawford CR, et al. Minimum scan speeds for suppression of motion artifacts in CT. Radiology , 1992, 185:37-42.
  • 6Rubin GD, Silverman SG. Helical (spiral) CT of the retroperitoneum. Radiol Clin North Am, 1995,33:903z932.
  • 7Becker CR, Knez A, Ohnesorge B, et al. Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating.A JR,2000,175:423-424.
  • 8Hong C, Becker CR, Huber A, et al. ECG-gated reconstructed multi-detector row CT coronary angiography : effect of varying trigger delay on image quality. Radiology,2001,220:712 -717.
  • 9Ghersin E, Litmanovich D, Ofer A, et al. Anomalous origin of right coronary artery: diagnosis and dynamic evaluation with multidetector computed tomography [J]. J Comput Assist Tomogr,2004,28(2): 293-294.
  • 10Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography[J]. Circulation, 2002, 106(16) :2051-2054.

共引文献207

同被引文献11

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部