大螺距双源CT诊断巨大冠状动脉瘤合并冠状动脉右心室漏、单冠状动脉畸形(英文)
被引量:1
A giant coronary aneurysm together with a coronary-right ventricular fistula and anomalous single coronary artery diagnosed with high-pitch dual-source CT
摘要
Introduction The second generation of dual-source CT systems is a new system allows computed tomoghaphy coronary angiography ( CTCA) examinations to be performed at high-pitch values of up to 3. 4[1-4]. In the HP acquisition mode that is unique to dual-source CT,the second detector system can be used to fill these gaps. By
出处
《中华临床医师杂志(电子版)》
CAS
2011年第20期6198-6200,共3页
Chinese Journal of Clinicians(Electronic Edition)
参考文献12
-
1Robert Goetti,Gudrun Feuchtner,Paul Stolzmann,Lotus Desbiolles,Michael Alexander Fischer,Christoph Karlo,Stephan Baumueller,Hans Scheffel,Hatem Alkadhi,Sebastian Leschka.High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates[J]. European Radiology . 2010 (11)
-
2Sebastian Leschka,Paul Stolzmann,Lotus Desbiolles,Stephan Baumueller,Robert Goetti,Thomas Schertler,Hans Scheffel,Andre Plass,Volkmar Falk,Gudrun Feuchtner,Borut Marincek,Hatem Alkadhi.Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience[J]. European Radiology . 2009 (12)
-
3Michael Lell,Mohamed Marwan,Tiziano Schepis,Tobias Pflederer,Katharina Anders,Thomas Flohr,Thomas Allmendinger,Willi Kalender,Dirk Ertel,Carsten Thierfelder,Axel Kuettner,Dieter Ropers,Werner G. Daniel,Stephan Achenbach.Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience[J]. European Radiology . 2009 (11)
-
4Karlo C,Leschka S,Goetti RP,et al.High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization. European Radiology . 2011
-
5Donati OF,Burg MC,Desbiolles L,et al.High-pitch 128-slice dual-source CT for the assessment of coronary stents in a phantom model. Acad Ra- diol . 2010
-
6Sommer WH,Albrecht E,Bamberg F,et al.Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT. American Journal of Roentgenology . 2010
-
7Achenbach S,Goroll T,Seltmann M,et al.Detection of coronary artery stenoses by low-dose,prospectively ECG-triggered,high-pitch spiral coro- nary CT angiography. JACC Cardiovasc Imaging . 2011
-
8Alkadhi H,Stolzmann P,Desbiolles L,et al.Low-dose,128-slice,dual-source CT coronary angiography: accuracy and radiation dose of the high- pitch and the step-and-shoot mode. Heart . 2010
-
9Sáez de Ibarra JI,Fernández-Tarrío R,Francisco Forteza J,Bonnín O.Giant coronary artery fistula between the left main coronary artery and the superior vena cava compli- cated by coronary artery dissection. Revista Espanola de Cardiologia . 2010
-
10Tsiflikas I,Brodoefel H,Reimann AJ,et al.Coronary CT angiography with dual source computed tomo-graphy in170patients. European Journal of Radiology . 2010
-
1孙凯,韩瑞娟,马利军,王利军,李立刚,陈九宏.心房颤动患者的低剂量、大螺距双源CT冠状动脉成像的可行性研究(英文)[J].中华临床医师杂志(电子版),2011,5(20):6027-6032. 被引量:1
-
2雍伟哲.北京协和医院引进中国首台双源CT机[J].中华医学信息导报,2006,21(21):11-11.
-
3贾付坤,张朝利,费军,李焕杰.双源CT设备临床运行经济效益分析[J].总装备部医学学报,2008(2):80-82.
-
4韩瑞娟,孙凯,李立刚,陈九宏.心脏电机械偶联与Flash双源CT冠状动脉成像在高心率患者中的应用(英文)[J].中华临床医师杂志(电子版),2011,5(21):6342-6350. 被引量:3
-
5孙凯,韩瑞娟,马利军,王利军,王志清,赵冬梅,王刚.大螺距双源CT前瞻性心电门控冠状动脉成像在高心率患者中的应用[J].中华临床医师杂志(电子版),2011,5(17):4962-4967. 被引量:3
-
6什么是科技论文的引言[J].实用医药杂志,2016,33(8):686-686.
-
7长跑过量会“伤心”[J].生活与健康,2014(6):5-5.
-
8谢安,臧益民,董秀珍,朱妙章,冯养止,孙启祥,王东,张琳.甲苯二异氰酸酯对右心室收缩功能的影响[J].心功能杂志,1992,4(2):77-80.
-
9何凡,沈毅,叶众.浙江省海岛居民两周患病率的影响因素[J].中国农村卫生事业管理,2006,26(2):31-33. 被引量:3
-
10励建安,陈伟.心脏的话(一)[J].祝您健康,1994,0(10):30-30.