期刊文献+

护轨对桥上无缝线路稳定性的影响 被引量:10

Guard Rail's Influence on the Stability of Continuously Welded Rail on Bridge
下载PDF
导出
摘要 运用ANSYS软件,建立铺设护轨的桥上无缝线路有限元模型,研究护轨中集聚不同温度力对桥上无缝线路稳定性的影响。结果表明:对于采用50kg·m-1钢轨铺设护轨半径大于1 200m和采用60kg·m-1钢轨铺设护轨半径大于800m的曲线线路,当护轨中集聚小于20℃的温度力时,铺设护轨可提高桥上无缝线路的稳定性,而对于采用50kg·m-1钢轨铺设护轨半径小于1 200m和采用60kg·m-1钢轨铺设护轨半径小于800m的曲线线路,当护轨中集聚大于20℃的温度力时,铺设护轨则会不同程度地降低桥上曲线无缝线路的稳定性,且半径越小,线路稳定性的降低越明显;对于桥上直线无缝线路,采用50或60kg·m-1钢轨铺设护轨后,当护轨中集聚小于30℃的温度力时,桥上无缝线路稳定性均可得到提高,且护轨温度力越小其稳定性提高程度越高。通过减小护轨中的温度力,可减少伸缩调节器的使用,提高桥上无缝线路铺设的温度跨度。 Using the ANSYS software,a finite element model of continuously welded rail on bridge(BCWR for short) with guard rail was established,the influences of different temperature force aggregated in guard rail on BCWR stability were investigated.The results indicate that,the BCWR stability of segments that the curve radius is larger than 1 200 m with 50 kg·m-1 guard rail and curve radius is larger than 800 m with 60 kg·m-1 guard rail can be improved when the guard rail temperature force is less than 20℃,but that of segments that the curve radius is less than 1 200 m with 50 kg·m-1 guard rail and curve radius is less than 800 m with 60 kg·m-1 guard rail may be decreased at different levels when the temperature force is more than 20℃.The smaller is the curve radius,the more explicit is the decrease of BCWR stability.For the straight line segment with 50 or 60 kg·m-1 guard rail,when the guard rail temperature force is less than 30 ℃,BCWR stability can be improved.The less is the temperature force of guard rail,the larger is the improvement of BCWR stability.Through reducing the temperature force of guard rail,the expansion rail joints can be decreased,and the temperature span of BCWR can be enlarged.
出处 《中国铁道科学》 EI CAS CSCD 北大核心 2012年第4期8-12,共5页 China Railway Science
基金 国家自然科学基金资助项目(51078320) 中央高校基本科研业务费科技创新项目(SWJTU09CX003)
关键词 桥上无缝线路 护轨 温度力 稳定性 Continuously welded rail on bridge Guard rail Temperature force Stability
  • 相关文献

参考文献5

二级参考文献26

  • 1陈秀方.无缝线路稳定性问题的最小温度力[J].铁道工务,1989,(4).
  • 2A Kish G Samavedam.CWR横向稳定性的最新试验研究[J].铁道建筑,1986,(7).
  • 3Tung Daxun. Distribution of Temperature Stresses Along the Continuously Welded Track [R]. American Railroad Engineering Association, Bulletin 692, 1983, 35--51.
  • 4Kish A, Samavedam G, Jeong D. Analysis of Thermal Bucking Tests on U. S. Railroads[R].Technique Report,NTIS-PB83-203554, 1982, 21--102.
  • 5Jeong D, Samavedam G, Kish A. Determination of Track Lateral Resistance from Lateral Pull Tests[R] . Final Report,NTIS-PB86-225612, 1986, 1--49.
  • 6Samavedam G, Kish A, Jeong D. Parametric Studies on Lateral Stability of Welded Rail Track [R]. Technique Report,NTIS-PB83-215517, 1983, 1--59.
  • 7Kish A, Samavedam G, Jeong D. Influence of Vehicle Induced Loads on the Lateral Stability of CWR Track [R]. Final Report, NTIS-PB85-168853, 1985, 1--93.
  • 8Luo Y. A Model for Predicting the Effect of Temperature Force of Continuous Welded Rail Track [C] . Proceedings of the Institution of Mechanical Engineers, Part F, 1999, 213: 117--124.
  • 9Nam-Hyoung Lim, Nam-Hoi Park , Young-Jong Kang. Stability of Continuously Welded Track [ J ]. Computers & Structures, 2003, 81 (22/23): 2219--2236.
  • 10Samavedam G, Kish A, Purple A, Schoengart J. Parametric Analysis and Safety Concepts of CWR Track Bucking [R].Final Report, NTIS-PB94-154648, 1993, 38--109.