摘要
为验证哈大客运专线室外信号设备在寒冷的环境下能否正常工作,对室外信号设备及车载设备、线缆进行了低温测试,测试结果表明:哈大客运专线ZPW-2000室外设备能满足低温-40℃技术指标要求。
Low temperature tests of outdoor signal devices,on-board devices and cables have been conducted to determine the normal operation of the outdoor signal devices on Harbin-Dalian Passenger Dedicated Line.The test results have shown that ZPW-2000 outdoor devices have met the specifications for operation at-40 ℃
出处
《铁道标准设计》
北大核心
2012年第5期144-146,共3页
Railway Standard Design
关键词
哈大客运专线
信号设备
低温试验
Harbin-Dalian Passenger Dedicated Line
Signal device
Low temperature test