期刊文献+

不同波长的散射介质后向散射光偏振度特性 被引量:6

Characteristics of Degree of Polarization of Backscattering Light in Scattering Medium at Different Wavelengths
下载PDF
导出
摘要 基于Stockes矢量,通过测量以线偏振光和圆偏振光入射时脂肪乳剂后向散射光的偏振度,研究了532nm、650nm和780nm三个波长的光与散射粒子粒径为325nm的脂肪乳剂溶液作用后,其后向散射光的偏振度特性.研究结果表明,对于入射线偏振光,780nm波长后向散射光中的线偏振光成分多于圆偏振光成分,而532nm波长则相反;对于入射圆偏振光,三个波长后向散射光中的圆偏振光成分均多于线偏振光成分;532nm波长的总偏振度高于650nm和780nm两个波长各自的总偏振度;线偏振光的保偏性优于圆偏振光的保偏性,但偏振光在散射介质中的穿透深度较小.因此,后向散射成像技术适用于物体表层成像,而且选择波长略大于粒径的线偏振光可以提高成像质量. The degree of polarization(DOP) of backscattering light in intralipid were measured based on Stokes vector.The characteristics of DOP were investigated when the interaction between polarized light and scattering midum were taken into account.The polarized light included three different wavelengths of 532 nm,650 nm and 780nm.The diameter of scattering particle was 325 nm.Experimental results show that the circularly polarized component in backscattering light is more than the linearly polarized component for linearly polarized incident light of wavelength of 532 nm.However,this conclusion is reverse for wavelength of 780 nm.In addition,the circularly polarized component is more than the linearly polarized component for three different wavelengths when circularly polarized incident light was used.Furthermore,the total DOP value of 532 nm was larger than that of 650 nm and 780 nm respectively.Linearly polarized light maintained polarization better than circularly polarized light,however,the penetrating depth through scattering medium of polarized light was short.So the imaging used backscattering light can be applied to image superficial objects.Besides,the imaging quality can be improved if the wavelength of incident light is a little bigger than the diameter of scattering particle.
作者 曹先平 孙萍
出处 《光子学报》 EI CAS CSCD 北大核心 2012年第5期608-613,共6页 Acta Photonica Sinica
基金 国家自然科学基金(No.61077007) 北京市自然科学基金(No.4102031)资助
关键词 后向散射 Stockes矢量 偏振度 线偏振光 圆偏振光 散射介质 Backscattering Stokes vector Degree of polarization Linearly polarized light Circularly polarized light Scattering medium
  • 相关文献

参考文献18

  • 1SHAO H,HE Y H,LI W. Polarization-degree Imaging contrast in turbid media:a quantitative study[J].Applied Optics,2006,(18):4491-4496.doi:10.1364/AO.45.004491.
  • 2SHUKLA P,PRADHAN A. Polarization-gated imaging in tissue phantoms:effect of size distribution[J].Applied Optics,2009,(32):6099-6104.doi:10.1364/AO.48.006099.
  • 3DEMOS S G,ALFANO R R. Optical polarization imaging[J].Applied Optics,1997,(01):151-155.doi:10.1364/AO.36.000150.
  • 4JACQUES S L,JESSICA C. R-R,LEE K,Imaging skin pathology with polarized light[J].Journal of Biomedical Optics,2002,(03):329-340.doi:10.1117/1.1484498.
  • 5LI X,JANAKA C R,YAO G. Polarization-sensitive reflectance imaging in skeletal muscle[J].Optics Ex-press,2008,(13):9927-9935.
  • 6ZHU Q,STOCKFORD I M,JOHN A. Experimental and theoretical evaluation of rotating orthogonal polarization imaging[J].Journal of Biomedical Optics,2009,(03):034006-031-10.doi:10.1111/j.1398-9995.2009.02226.x.
  • 7SANKARAN V,WALSH J T Jr,MAITLAND D J. Comparative study of polarized light propagation in biological tissues[J].Journal of Biomedical Optics,2002.300-306.doi:10.1117/1.1483318.
  • 8李伟,何永红,马辉.偏振门用于对散射介质成像的蒙特卡罗模拟研究[J].光子学报,2008,37(3):518-522. 被引量:7
  • 9邓勇,鲁强,骆清铭.混浊介质中线偏振光和圆偏振光的后向漫散射特征[J].光子学报,2007,36(3):525-529. 被引量:2
  • 10LU S Y,CHIPMAN R A. Mueller matrices and the degree of polarization[J].Optics Communications,1998,(4):11-14.doi:10.1245/s10434-009-0863-0.

二级参考文献25

  • 1张琳,张连顺,许棠,张春平,田建国.生物组织光学参数的离体和在体无损测量[J].光子学报,2004,33(11):1377-1381. 被引量:22
  • 2贺忠海,徐可欣,苏翼雄.透射光偏振度与散射次数关系的研究[J].光子学报,2005,34(4):547-549. 被引量:5
  • 3胡锐,邓勇,鲁强,骆清铭.混浊介质二维后向漫散射穆勒矩阵的测量[J].光子学报,2006,35(6):910-914. 被引量:5
  • 4BREZINSKI M E, FUJIMOTO J G. Optical coherence tomography:High-resolution imaging in nontransparent tissue[J]. IEEE J Select Topics Quantum Electron, 1999,5(4):1185-1192.
  • 5GAYEN S K,ALRUBAIEE M,SAVAGE H E,et al. Parotid gland tissues investigated by picosecond time-gated and optical spectroscopic imaging techniques[J].IEEE J Select Topics Quantum Electron, 2001,7(6):906-911.
  • 6GAUDERON R, LUKINS P B, SHEPPARD C J R, et al.Effect of a confocal pinhole in two-photon microcopy[J].Microsc Res and Tech, 1999,47(2) :210- 214.
  • 7BARTLETT M,JIANG H B. Measurement of particle size distribution in multilayered skin ohantoms using polarized light spectroscopy[J].Physical Review E, 2002,65 ( 3 ):031906-1-031906-8.
  • 8BACKMAN V, WALLACE M B, PERELMAN L T, et al.Diagnosing cancers using spectroscopy [ J ]. Nature, 2000,406(6) :35-36.
  • 9AMELINK A, BARD M P L, BURGERS S A, et al. Single-scattering spectroscopy for the endoscopic analysis of particlesize in superficial layers of turbid media[J].Appl Opt, 2003,42(19) ,4006-4101.
  • 10JACKSON M. Introductory lecture from biomolecules to biodiagnostics: Spectroscopy does it all[J]. Faraday Discuss,2004,126(1):1-18.

共引文献7

同被引文献59

引证文献6

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部