期刊文献+

Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods 被引量:1

Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods
下载PDF
导出
摘要 Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine. Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第4期218-222,共5页 药物分析学报(英文版)
关键词 GANCICLOVIR related substances high performance liquid chromatography high performance liquid chromatography/mass spectrometry ganciclovir related substances high performance liquid chromatography high performance liquid chromatography/mass spectrometry
  • 相关文献

参考文献13

  • 1木尼热.阿布都克热木,王楠楠,唐玉海,木合塔尔.吐尔洪.流动注射-化学发光法测定阿昔洛韦和更昔洛韦[J].西安交通大学学报(医学版),2007,28(6):707-710. 被引量:7
  • 2常珍,曹桂芳,高雷,赵红,况斌.更昔洛韦含量及有关物质的HPLC测定[J].药物分析杂志,2005,25(9):1058-1060. 被引量:11
  • 3梁翠荣,徐志洲,董蓬.HPLC测定更昔洛韦中有关物质的含量[J].中国药科大学学报,2004,35(2):135-137. 被引量:19
  • 4Dankner WM.Ganciclovir. Seminars in Pediatric Infectious Diseases . 1996
  • 5Bengi U,Burcu D,Sibel AO.Electrochemical studies of gan-ciclovir at glassy carbon electrodes andits direct deter mination in serum and phar maceutics by square wave and differential pulse voltammetry. Analytica Chimica Acta . 2005
  • 6Wang YM,Xiao J.Analysis of ganciclovir andits related sub-stances using HPLC and gradient elution. Phar m Clin Res . 2008
  • 7Merodio M,Campanero MA,Mirshahi T,et al.Development ofa sensitive method for the determination of ganciclovir by reversed-phase high-performance liquid chromatography. Journal of Chromatography A . 2000
  • 8Asberg A,Hansen C. N,Reubsaet L.Determination of Ganciclovir in Different Matrices from Solid Organ Transplanted Patients Treated with a Wide Range of Concomitant Drugs. Journal of Pharmaceutical and Biomedical Analysis . 2007
  • 9Dieterich,DT,Chachoua,A,Lafleur,F,Worell,CV.ganciclovir treatment of gastrointestinal infections caused by cytomegalovirus in patients with AIDS. Reviews of Infectious Diseases . 1988
  • 10DarwishIA,,Khedr AS,Askal HF,et al.Simplefluorimetric methodfordetermination of certain antiviral drugs via their oxidation with cerium(IV). Il Farmaco . 2005

二级参考文献18

  • 1杨梅,邹原,于世钧,李晓辉.阿昔洛韦-过氧化氢-钴(Ⅱ)化学发光体系的研究和应用[J].分析化学,2004,32(9):1237-1239. 被引量:17
  • 2国家药典委员会编.药品标准(新药转正标准第二十四册)[S].,.885.
  • 3.中华人民共和国药典(2000年版)[Z]:二部[M].北京:化学工业出版社,2000.332-333.
  • 4Stephen AS. Ganciclovir therapy for CMV infection. New York:MardelDekker Inc,1991.1.
  • 5WS1-(X—015)-2001Z.国家药品标准.[S].,..
  • 6Martindale SC. The complete drug reference [M]. London: Pharmaceutical Press, 2002: 612.
  • 7Tadepalli SM, Quinn RP. Scintillation proximity radioimmunoassay for the measurement of acyclovir [J]. J Pharma Biomed Anal, 1996, 15:157-163.
  • 8Chu F, Kiang C, Sung M, et al. A rapid, sensitive HPLC method for the determination of ganciclovir in human plasma and serum [J].J Pharma Biomed Anal, 1999, 21:657-667.
  • 9Merodio M, Campanero M, Mirshahi T, et al. Development of a sensitive method for the determination of ganciclovir by reversed-phase high-performance liquid chromatography [J]. J Chromatogr A, 2000, 870 : 159-167.