期刊文献+

Identification of serum biomarkers for diagnosing stage Ⅰ lung adenocarcinoma by MALDI-TOF mass spectrometry 被引量:1

Identification of serum biomarkers for diagnosing stage Ⅰ lung adenocarcinoma by MALDI-TOF mass spectrometry
下载PDF
导出
摘要 Objective To identify specific biomarkers that could improve early diagnosis of lung adenocarcinoma using matrix-assisted laser desorption/ionization (MALDI) technology. Methods Serum samples were isolated from 17 patients with stage Ⅰ lung adenocarcinoma and 17 age-and sex-matched healthy controls,and the serum proteomic profiles were obtained by matrix-assisted laser desorption ionization time of flight (MALDI-TOF) mass spectrometry. Results Compared with healthy control group,two highly expressed potential biomarkers were identified with the relative molecular weights of 6 631.64 Da and 4 964.21 Da. The two best novel protein peaks were automatically chosen for the system training and the development of the constructed model. The constructed model was then used to test an independent set of masked serum samples from 15 lung adenocarcinoma patients and 22 healthy individuals. The analysis yielded a sensitivity of 93.3%,and a specificity of 95.5%. Conclusion These results suggest that MALDI-TOF-MS ProteinChip technology is a quick,convenient,and high-output analyzing method that is capable of selecting several relatively potential biomarkers from the serum of lung adenocarcinoma patients and may have a clinical value in the future,and will provide clues to identifying new serologic biomarkers of lung adenocarcinoma. Objective To identify specific biomarkers that could improve early diagnosis of lung adenocarcinoma using matrix-assisted laser desorption/ionization (MALDI) technology. Methods Serum samples were isolated from 17 patients with stage Ⅰ lung adenocarcinoma and 17 age-and sex-matched healthy controls,and the serum proteomic profiles were obtained by matrix-assisted laser desorption ionization time of flight (MALDI-TOF) mass spectrometry. Results Compared with healthy control group,two highly expressed potential biomarkers were identified with the relative molecular weights of 6 631.64 Da and 4 964.21 Da. The two best novel protein peaks were automatically chosen for the system training and the development of the constructed model. The constructed model was then used to test an independent set of masked serum samples from 15 lung adenocarcinoma patients and 22 healthy individuals. The analysis yielded a sensitivity of 93.3%,and a specificity of 95.5%. Conclusion These results suggest that MALDI-TOF-MS ProteinChip technology is a quick,convenient,and high-output analyzing method that is capable of selecting several relatively potential biomarkers from the serum of lung adenocarcinoma patients and may have a clinical value in the future,and will provide clues to identifying new serologic biomarkers of lung adenocarcinoma.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2009年第2期134-137,共4页 药物分析学报(英文版)
关键词 lung neoplasm ADENOCARCINOMA BIOMARKER matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS) PROTEOMICS lung neoplasm adenocarcinoma biomarker matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS) proteomics
  • 相关文献

参考文献1

共引文献1

同被引文献4

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部