期刊文献+

EFFECTS OF THROMBOLYSIS WITH ULTRASOUND ON THE STRUCTURE OF ERYTHROCYTE AND ITS SAFETY THRESHOLD 被引量:1

EFFECTS OF THROMBOLYSIS WITH ULTRASOUND ON THE STRUCTURE OF ERYTHROCYTE AND ITS SAFETY THRESHOLD
下载PDF
导出
摘要 The study was to investigate thrombolysis in vitro with ultrasound, and to discuss effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold under different ultrasound intensity and exposure time. The structure of erythrocyte in thrombus was evaluated under light microscope. The relationship between the structure of erythrocyte in thrombus and ultrasound intensity and exposure time was obtained. The results showed that ultrasound eliminated the thrombus. According to the change of the structure of erythrocyte in thrombus and ultrasound intensity and exposure time, the effects of thrombolysis with ultrasound could be divided into three kinds of areas: the A, B, C area. The area A was the safe area, the area B was the relatively safe area, and the area C was the irreversible damage area. The study suggested that ultrasound intensity and exposure time had significant impact on the structure of erythrocyte. Stronger ultrasound intensity or longer exposure time could cause erythrocytes irreversible damage. It could accelerate thrombolysis and shorten the exposure time that the ultrasound intensity was little bit increased. The study of effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold were important for practical applications. The study was to investigate thrombolysis in vitro with ultrasound, and to discuss effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold under different ultrasound intensity and exposure time. The structure of erythrocyte in thrombus was evaluated under light microscope. The relationship between the structure of erythrocyte in thrombus and ultrasound intensity and exposure time was obtained. The results showed that ultrasound eliminated the thrombus. According to the change of the structure of erythrocyte in thrombus and ultrasound intensity and exposure time, the effects of thrombolysis with ultrasound could be divided into three kinds of areas: the A, B, C area. The area A was the safe area, the area B was the relatively safe area, and the area C was the irreversible damage area. The study suggested that ultrasound intensity and exposure time had significant impact on the structure of erythrocyte. Stronger ultrasound intensity or longer exposure time could cause erythrocytes irreversible damage. It could accelerate thrombolysis and shorten the exposure time that the ultrasound intensity was little bit increased. The study of effects of thrombolysis with ultrasound on the structure of erythrocyte and its safety threshold were important for practical applications.
作者 严碧歌
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2006年第2期139-141,共3页 药物分析学报(英文版)
基金 The work was supported by the National Natural Science Foundation of China ( No.10074043) and the Natural ScienceFoundation of Shaanxi Province (No.2003A05) .
关键词 ULTRASOUND THROMBOLYSIS erythrocyte structure safe area ultrasound thrombolysis erythrocyte structure safe area
  • 相关文献

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部