摘要
[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From the aspects of solid-phase extraction column,elution solvent,elution volume,elution speed and so forth,the test conditions of SPE-HPLC method were optimized,and trace amount of PAHs in urban sewage was determined.[Result] The optimized solid-phase extraction conditions were SUPELCLEAN LC-18 solid-phase extraction column,methylene dichloride as elution solvent,15 ml elution volume,2 ml/min elution speed,5 ml/min loading speed,1 000 ml water with 200 ml methanol loading volume.Under the optimized extraction conditions,the recovery was high,namely 76.3%-105.2%;relative standard deviation was 3.8%-6.0%,showing good precision;detection limit was low,only 0.000 8-0.048 0 μg/L.[Conclusion] This method is user-friendly,with high sensitivity and good precision,and suitable for continuous determination of a large volume of water samples.
[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From the aspects of solid-phase extraction column,elution solvent,elution volume,elution speed and so forth,the test conditions of SPE-HPLC method were optimized,and trace amount of PAHs in urban sewage was determined.[Result] The optimized solid-phase extraction conditions were SUPELCLEAN LC-18 solid-phase extraction column,methylene dichloride as elution solvent,15 ml elution volume,2 ml/min elution speed,5 ml/min loading speed,1 000 ml water with 200 ml methanol loading volume.Under the optimized extraction conditions,the recovery was high,namely 76.3%-105.2%;relative standard deviation was 3.8%-6.0%,showing good precision;detection limit was low,only 0.000 8-0.048 0 μg/L.[Conclusion] This method is user-friendly,with high sensitivity and good precision,and suitable for continuous determination of a large volume of water samples.
作者
WANG Jing-fei1,KANG Quan-ying1,RONG Nan1,2,WU Yi-hong1,LI Hong-bo1 1.Hebei Provincial Academy of Environmental Science,Hebei Provincial Laboratory of Water Environmental Science,Shijiazhuang 050037,China
2.College of Chemistry and Environmental Science,Hebei University,Baoding 071002,China
基金
Supported by National Science and Technology Key Project of Water Pollution Control and Management (2012ZX07209-003)